A CGH2 tube trailer-tractor was hit at the rear by another vehicle, an empty flatbed trailer-tractor. Because of the collision, at least two tube safety valves were broken. The released hydrogen…
The accident occurred in the hydro-cracking unit, specifically in its sulphur recuperating system. The location was on a 8" piping, which cracked at a a 90° bend. Due to the loss of confinment, a…
Hydrogen escaped when a venting valve was opened for the inspection of a cap. The escaped hydrogen caught fire, resulting in the death of 4 people, injuries to others 3 and damages to the plant.
The incident occurred at a silane production plant. A ‘neutralization container’, part of the "Contact Mass Preparation" process unit, exploded. The bursting was caused by the accidental production…
During the polymerization of ethylene in a 750 litres pressurized reactor, an exothermic runaway decomposition occurred and ethylene and its decomposition products were released through the two…
A mechanical failure occurred in a gasification reactor, which caused a violent (abrupt, sudden) depressurisation of the reactor. The consequences were the projection of tiles of the refractory…
Fire in bulk hydrogen storage compound. Pressure gauge shut off valve spindle blown out (could be completely unscrewed and removed). The subsequent leak ignited by unknown source. No injuries…
The accident occurred in the Reactor 6 used to carry out the hydrogenation of a pharmaceutical intermediate. The operation of the plant was organized in two shifts. Since the hydrogenation at Reactor…
The accident occurred in a plant producing synthesised active ingredients for the pharmaceutical industry. An explosion and a fire occurred in one of the workshops of the plant. The chemical reaction…
A 24" pipe carrying synthesis gas (Hydrogen = 43. 5%, Nitrogen = 14. 08%, Methane = 0. 2%, Carbon Dioxide = 12. 3%, Water = 29. 3% by volume) ruptured. About 60 kg of hydrogen contained in the gas…
Release of gas from a coking plant on a gas holder which ignited causing a fire. The accident took place during repair works. The gas was made of 65 % of hydrogen , 25 % of methane , 4. 1 % of carbon…
A trailer-tractor transporting hydrogen cylinders veered off the road to the right at around for unclear reasons and eventually tipped over to the left. Part of the 4,000 cubic meters of hydrogen…
A fire broke out affecting the heavy fuel purification plant of the refinery. The incident could have originated by the failure of one of the following plant components: - pipes leading to the…
A liquid hydrogen tanker was returning empty to its home terminal. When the drivers noted that the inner vessel was building pressure. The drivers advised their supervisor and were advised to find a…
A liquid hydrogen tanker was returning to the base after having deliver data customer site. The tank was empty. Nevertheless, on the road the drivers noticed a continuing elevated pressure. To avoid…
While de-plugging a cooling circuit, a blockage suddenly released, causing a heavy movement of a flexible hose connected to the system. The flexible hose hit several small pipes and one employee…
Malfunctioning of the non-return valve of the hydrogen compressor has caused the pressure between the hydrogen bottle and the compressor to rise to the maximum allowed pressure of 275 barg. As a…
A liquid hydrogen tanker was travelling on a highway, when the driver noticed vapour exiting the rear tanker cabinet. The driver stopped the vehicle in a safe location and discovered that the vapour…
The incident happened during a liquid hydrogen delivery at a customer site. When the drivers were pressuring up the tanker for product transfer, the safety relief system rupture disc failed…
A car driving out from a private street hits the bus on the its right side just behind the rear tires