Explosions in a reactor used to hydrogenate pharmaceutical intermediates
The accident occurred in the Reactor 6 used to carry out the hydrogenation of a pharmaceutical intermediate. The operation of the plant was organized in two shifts. Since the hydrogenation at Reactor 6 would have taken at least 30 hours, it was not possible to complete the reaction during a single shift. The reaction was commenced at 8:00 a. m. on the day of the accident and, at 11:50 p. m. , the shift chemical operator closed down the system as follows:- he shut off the hydrogen addition at the reactor and closed the valve at the hydrogen cylinder bank;- the reactor's agitator was turned off and the reactor was left isolated with an hydrogen atmosphere over the liquid. No nitrogen inerting was used. The operator checked the reactor's control panel which showed normal operating temperature and pressure. The operator was also in control of Reactor 5 which he shut down in a similar manner. At approximately midnight, as the chemical operators were changing in their locker room, they heard a loud explosion coming from the process area. As they evacuated the building, they observed a fire around Reactor 6. The area sprinkler system was automatically activated and quenched the fire. It was noticed that one operator was missing. He came to the assembly point a few minutes later and said that when the explosion occurred he was trapped in the mill room weighing finished product. He could not exit by the process area and had to exit through a hatch on the floor, jump onto a rotary dryer below and climb down to the ground floor. A second explosion occurred a few minutes later. A fire with a characteristic black smoke resulted, indicative of a solvent fire. The sprinkler system extinguished this fire. A short while later, the fire services arrived and put out small localized fires on the ground floor around Reactor 6. The building was left vacant for the rest of the night.
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments
The INITIATING cause was probably a release of hydrogen triggered by the malfunctioning of the agitator. The maintenance record on the agitator showed that it malfunctioned on numerous occasions. It was felt that the agitator possibly malfunctioned again allowing a hydrogen leak. As the reactor was located in a general process area with plants operating nearby, the released hydrogen could easily have found an ignition source as some of the electrical plants operating nearby were not suitable for use with hydrogen. The investigation showed that the reactor's pressure relief line did not operate as the bursting disc was found to be intact.