Skip to main content

Release from a LH2 tanker (423)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Release from a LH2 tanker

A liquid hydrogen tanker was travelling on a highway, when the driver noticed vapour exiting the rear tanker cabinet. The driver stopped the vehicle in a safe location and discovered that the vapour return valve was not sufficiently closed. The driver tightly closed the valve and the vapour leak was secured. The trip was completed safely without any further incident.
Event Date
June 21, 1997
Record Quality Indicator
Region / Country
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments

The INITIATING cause was the vapour return valve not properly closed, similar events have been attributed this to road vibrations. The ROOT CAUSE was a design which did not took into account the whole range of mechanical solicitations which the pressure control system of the trailer could experiment when travelling.

Facility Information
Application
LH2 tanker
Specific Application Supply Chain Stage
Components Involved
valve
Storage/Process Medium
Storage/Process Quantity
3483
Design Pressure
0
Location Type
Operational Condition
Consequences
Number of Injured Persons
0
Number of Fatalities
0
Environmental Damage
0
Currency
Property Loss (onsite)

15

Property Loss (offsite)

0

Lessons Learned
This incident is very similar to other, such as the 070, which attributed to road vibrations the opening of the vapour return valve. Independently from the root cause, releases of hydrogen in the control cabinet can generate flammable mixture with explosion potential, as found out by J. Song et al. , Hydrogen leakage and diffusion in the operational cabin of hydrogen tube bundle containers: A CFD study, International Journal of Hydrogen Energy 88 (2024) 986-1002. The passive ventilation of the involved cabinet is unknown, however, the fact that the driver opened it without further precautious measures indicated a lack of attention to explosion hazards.
Event Nature
Emergency Action
The driver closed the vapour return valve stopping the leak.
Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
Detonation
No
Deflagration
No
High Pressure Explosion
No
High Voltage Explosion
No
References
References

Incident I-1999010487 of the US Pipeline and Hazardous Materials Safety Administration PHMSA: https://portal. phmsa. dot. gov/analytics/saw. dll?Portalpages&PortalPath=%2Fshared%2FPublic%20Website%20Pages%2F_portal%2FHazmat%20Incident%20Report%20Search (accessed September 2024)