Skip to main content

Collision and fire from a CGH2 trailer (418)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Collision and fire from a CGH2 trailer

A CGH2 tube trailer-tractor was hit at the rear by another vehicle, an empty flatbed trailer-tractor. Because of the collision, at least two tube safety valves were broken. The released hydrogen ignited and the fire engulfed the other eight cylinders, which over-heat, causing the pressure relief valve to activate and release the whole content (350 kg).
Event Date
July 15, 1984
Record Quality Indicator
Region / Country
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes
Cause Comments

The INITIATING CAUSE was the damage to the pressure control system caused by the collision caused by another vehicle. The safety measures operated as expected. The ROOT CAUSE is difficult to determine. A better design could guarantee stronger protection of the trailer pressure control system, and therefore the reduction of the probability of an escalation. However, it is difficult to take into account all possible crash scenarios generated by traffic.

Facility Information
Application
CGH2 tube trailer
Specific Application Supply Chain Stage
Components Involved
safety valve
Storage/Process Medium
Storage/Process Quantity
350
Actual Pressure
20
Design Pressure
20
Location Type
Operational Condition
Pre-event Summary

The trailer consisted of ten tubes.

Consequences
Number of Injured Persons
0
Number of Fatalities
0
Environmental Damage
0
Property Loss (offsite)

0

Lessons Learned
The safety measures operated as expected. A better design of the protective barrier at the rear of the trailer could guarantee stronger protection of the trailer pressure control system, and therefore the reduction of the probability of an escalation. However, it is difficult to take into account all possible crash scenarios generated by traffic.
Event Nature
Emergency Action
The actions are not reported. Time of the fire also unknown. Since this was a case of immediate release and ignition, It is very probable that the fire was left extinguish, possibly by cooling the tubes, before starting to intervene to recover the vehicles.
Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
Detonation
No
Deflagration
No
High Pressure Explosion
No
High Voltage Explosion
No
References
References

Incident I-1984070441 of the US Pipeline and Hazardous Materials Safety Administration PHMSA: https://portal. phmsa. dot. gov/analytics/saw. dll?Portalpages&PortalPath=%2Fshared%2FPublic%20Website%20Pages%2F_portal%2FHazmat%20Incident%20Report%20Search (accessed September 2024)