Skip to main content

Release from a hydrogen pipeline (933)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Release from a hydrogen pipeline

During maintenance work on a gas pipeline carrying hydrogen , a worker hears a leak at about at a bridge. The operator measures an concentration of 3% of the low flammability limit at few centimetres from the leak, and no detection beyond 25 cm. The area was highly ventilated. The technicians secured the area, isolated the section five hours later and started the controlled gas release. after two additional hours the pressure had reduced to zero and they started the nitrogen inerting. The pipe was repaired the next day.
Event Date
April 18, 2013
Record Quality Indicator
Region / Country
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes
Facility Information
Application
Pipeline
Specific Application Supply Chain Stage
Components Involved
hydrogen pipeline, 80 mm diameter, 75 bar pressure
Storage/Process Medium
Actual Pressure
7
Design Pressure
7
Location Type
Operational Condition
Pre-event Summary
The begin of the leak was unknown. The leak was detected during maintenance work, what does not mean that it started at that moment. The pipeline section (diamater DN80) dated back to 1988.
Consequences
Number of Injured Persons
0
Number of Fatalities
0
Event Nature
Emergency Action
14. 30 detection of the leak. Area secured,19:15 Isolation of the pipeline section20:00 Start controlled emptying23:00 Pipeline pressure at zero, start of nitrogen injectionDay after: repair of the leak
Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Release Pressure (bar)
75.00
Ignition Source
Detonation
No
Deflagration
No
High Pressure Explosion
No
High Voltage Explosion
No
References
References

Event description in the French database ARIA https://www. aria. developpement-durable. gouv. fr/accident/43705/ (accessed September 2020)