The incident happened during a liquid hydrogen delivery at a customer site. When the drivers were pressuring up the tanker for product transfer, the safety relief system rupture disc failed…
A hydrogen leak occurred on a flange located on a pipe coming from the hydrogen storage tank. The staff was confined and the Internal Operation Plan was launched. Helium was injected in the tank and…
A small release of hydrogen occurred after the collision between a truck containing liquid hydrogen and a truck containing manganese dioxide on a highway. Due to the release, the traffic was…

The release occurred at a composite pressure vessel on the roof of a refuelling station (in the form of a ISO-container). The leak occurred on a treated connection to the vessel. The vessel…

A leak occurred on a rack containing 12 cylinders of hydrogen (50 l at 200 bar each) delivered by a lorry inside the fenced storage area of a bulb manufacturing plant. The plant’s safety manager…
The vent occurred at a hydrogen refuelling station (HRS) of a research laboratory (not public) serving heavy- and light-duty vehicle. The affected dispenser was a 700-bar dispenser for light-duty use…
A hydrogen leak alarm was received in the control room from the reformer of the hydrogen plant of a chemicals manufacturing facility. The reformed was depressurised and the leak stopped. The leak was…
A release of hydrogen took place in a metal cold rolling workshop. The hydrogen leaked from a cylinder of 15 m3, which was part of a storage system of 250 m3. Half of the workshop and the surrounding…
In a plant manufacturing chlorate products, a hydrogen leak occurred via the water drainage outlet onto the factory floor. Pressure in the hydrogen line increased because the hydrogen pipes were…
Following the breakdown of a piston rod, a mixture of hydrogen and light hydrocarbons was released from the fresh hydrogen compressor of an oil refinery. The rod broke down because of stress…
During the start-up operation (phase) of a cryogenic unit, a separator exploded, releasing ethane, ethylene, methane and hydrogen. The bursting of a tank was caused by a 1600 mm long incipient crack…
The event was initiated by the burst of a rupture disc on a reactor during a hydrogenation process. The hydrogenation reaction occurs under pressure in a tank containing 3,000 l of a mixture of…
The accident occurred on one of the heat exchangers of the hydro-desulphurisation unit. The role of the exchanger , located between the charge pumps and the furnace, was to heat the charge using the…
A release of contents of a pressure vessel occurred when a longitudinal weld tore open. The vessel had been shut down and had just been put into use again when the incident occurred. The gas mixture…
The event occurred at the hydrogenation unit of a pharmaceutical company. 145 kg of hydrogen were released the atmosphere at the gas circulation pump, due to a maintenance error . A specialist…
During a stop of the operations for maintenance and repairs, a worker was cold-cutting a hydrogen piping supposedly purged before. This caused a release of hydrogen. Realising this, the worker…

While disconnecting the liquid hydrogen filling line from the tanker, hydrogen escaped burning the man who was holding the hose; he was burned on hands and stomach. [Ordin, NASA (1974)]

During an LH2 transfer from a tanker, the burst disc ruptured at 50 psi (ca. 3. 5 bar). The operator had turned on the pressure valve and left it unattended, permitting pressure build-up past the…

While pressurizing a liquid hydrogen tanker for the transfer, a rupture disc burst. The tanker pressure was 22 psig (ca. 1. 5 bar). The relief valve was set at 27 to 29 psig (1. 9 to 2 bar). The…

The operator detected a leak of aerosol hydrocarbons (diesel, hydrogen and hydrogen sulphide) in the diesel desulphurisation unit, causing a release of hydrogen and hydrogen sulphide at the top of…