Skip to main content

Release from the dispenser of a refuelling station (803)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Release from the dispenser of a refuelling station

The vent occurred at a hydrogen refuelling station (HRS) of a research laboratory (not public) serving heavy- and light-duty vehicle. The affected dispenser was a 700-bar dispenser for light-duty use supplied by an on-site gaseous storage of approx. 600 kg. The leak occurred due O-ring extrusion and/or failure, on a medium-pressure manual isolation ball valve (normally open). The valve was connected to the end plug of a medium pressure tank. The failure of an O-ring created an external leak which could not be isolated. The released quantity were small, in the 1 to 2 kg range. The leak was audible, but the hydrogen did not ignite and activated a safety sensor. This leak occurred during the recommissioning of the medium pressure system following extended downtime and rebuild of a system that had been originally installed at a different facility.
Event Date
December 20, 2021
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments
The INITIATING CAUSE was the failure of a O-ring. The ROOT CAUSE is related not only to a material failure, but also to the fact that the event occurred at the recommissioning of the medium pressure system, originally installed at a different facility, and after extended downtime. Ageing may have played a role in this case.
Facility Information
Application Type
Application
HRS (70 for LDV & HDV)
Specific Application Supply Chain Stage
Components Involved
dispenser, valve, o-ring
Storage/Process Medium
Storage/Process Quantity
600
Actual Pressure
70
Design Pressure
70
Location Type
Operational Condition
Consequences
Number of Injured Persons
0
Number of Fatalities
0
Environmental Damage
0
Property Loss (onsite)

0

Property Loss (offsite)

0

Post-event Summary

This is a near-miss

Lessons Learned
The safety system worked as expected.
Event Nature
Emergency Action
Probably just an automatic shut down
Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
Detonation
No
Deflagration
No
High Pressure Explosion
No
High Voltage Explosion
No
References
References

A. Al-Douri et al. , Populating the Hydrogen Component Reliability Database (HyCReD) with Incident Data from Hydrogen Dispensing, paper ID232, Proceedings of ICHS 2023 https://hysafe. info/uploads/papers/2023/232. pdf (accessed August 2024)

A detailed analysis was presented by Clark et al. at the 2024 Center for Hydrogen Safety Americas Conference The resentation is behind a paywall, but the abstract is available on line: https://proceedings. aiche. org/conferences/center-hydrogen-safety-conference/2024/proceeding/paper/lessons-learned-medium-pressure-tank-leak-nrels-hydrogen-refueling-station (accessed January 2025)