A gas manufacturing plant, one pallet consisting of nine (9) cylinders fell to the ground. The discharge valve of one cylinder (261 cubic feet of hydrogen) was damaged and the entire hydrogen…

An explosion, followed by a fire, happened in an oven belonging to the hydro-treatment unit. Following a shutdown, the tube, containing only gaseous products and hydrogen, had been affected by…
The event occurred while starting a new production cycle. The production supervisor issued specific instruction on a new production cycle to a technician. The technician did not follow them in the…
The leak occurred on a process pipe of a pressurized at 17 bar and located 3. 5 m from the ground The gaseous mixture composed of hydrogen, methane and hydrogen sulphide (density: 0. 6) was released…
The event occurred during the decommissioning of a nuclear power plant. It involved a tank containing 100 kg of residual sodium from the decommissioned experimental nuclear reactor which was using…
Following a loss of power the failure of a backup battery causes an alarm in a hydrogen storage facility. Consequently, a valve on the purge circuit and 30 m3 of hydrogen is released to the…
The event occurred at the factory producing multilayer circuit boards by a multistep dip operation. An employee inadvertently mixed 55 gal of 50 percent hydrogen peroxide into 110 gal of 30 percent…
Hydrogen leaked from a hydrogen compressor, ignited causing an explosion and a fire. The hydrogen fire further ignited roofing materials which had fallen down as the result of the explosion. The…
The incident occurred in an electrostatic filtration unit. When flushing with air during the start-up phase of a sulphonation plant, an explosion occurred in the upper part of the electrostatic…
An explosion occurred in a electrolyser cell, blowing off the cell's vent cover and severing a low-pressure chlorine gas pipeline. , what caused a release of chlorine in the building, The event…
The explosion took place in the hydrogen gasometer. The bell in the gasometer was lifted 15-20 m straight up and cracked. The cover fell down on the pipe bridge besides the gasometer. The cylindrical…
The explosion occurred while starting up for the first time a hydrogenation reactor. The reactor was being commissioned, by performing tightness tests under hydrogen atmosphere at very high pressure.…
The bolts on a not further specified industrial facility failed after approximately 4000 hours in service (approximately 18 months in service). Their failure bolts causedH2S leaks. The bolts…

A Bourdon tube ruptured in pressure gauge after 528 hours of operation in LH2. The alarm sounded, the system was isolated and then vented. [Ordin, NASA (1974)]

A fire and a series of explosions occurred on a petrochemical plant, causing damage to process vessels, containment walls and process utility piping. It is believed that lightning struck a two story…
On the way home, a trailer/truck overturned due to excessive speed, causing the hydrogen bundles to fall. It was transporting two bundles with 30 cartridges each. One of the bundle valves broke,…
The incident occurred during its delivery of bundle of 28 cylinders to a metal manufacturing company. A hydrogen leak occurred due to due to a wrong operation of the the truck crane. While loading an…

A CGH2 tube-trailer lost control, left the roadway, and went into a 1 1/2 foot ditch, traveling approx. 50 feet in the ditch. The soft ground in the ditch caused the trailer to over turn, sliding…

A tube trailer-tractor transporting compressed hydrogen was travelling on a highway, when the driver lost the control of the vehicle trying to avoid an obstacle on the road. The vehicle collided with…
A lorry crashed into a hydrogen tube trailer with considerable speed on the highway A1 near Cologne. The lorry driver was killed. Gas escaped from tubes and valves of three of the nine tanks and was…