An explosion on a hydrogenation reactor of a pharmaceutical products plant (252)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

An explosion on a hydrogenation reactor of a pharmaceutical products plant

The explosion occurred while starting up for the first time a hydrogenation reactor. The reactor was being commissioned, by performing tightness tests under hydrogen atmosphere at very high pressure. The rupture of one of the seals caused a hydrogen release followed by the auto ignition of a 30 litre air/hydrogen mixture. Five employees were injured. Material damage was confined to the immediate perimeter of the reactor. The hydrogen detectors controlling the closing of the H2 supply valve had not yet been installed. Nevertheless, their absence was not critical thanks to the prompt reaction taken by employees. The preliminary tests carried out under nitrogen were insufficient.
Event Date
October 31, 1995
Record Quality Indicator
Region / Country
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments
The INITIATING cause was the failing of a seal under hydrogen pressure during a tightness test. The root cause was the ill-designed or ill-performed commissioning procedure. The previous tightness under nitrogen were performed or designed in a way that did not identify the release event which occurred under hydrogen. The cause classification could be ‘operation’ or ‘design’.
Facility Information
Application Type
Application
Production of pharmaceutical products
Specific Application Supply Chain Stage
Components Involved
Hydrogenation reactor, seals
Storage/Process Medium
Location Type
Operational Condition
Pre-event Summary
The reactor had been installed for the first time, and the incident occurred during the commissioning tests.
Consequences
Number of Injured Persons
5
Number of Fatalities
0
Environmental Damage
0
Post-event Summary

Five employees experienced burns, suffered from ear pain due to the overpressure and were hospitalised. Among them, two employees were hospitalised for over 48 hours (humming sound in the ears). Material damage was limited to the area around the reactor.

Lessons Learned
As a rule, tightness tests have to performed with non-flammable gas, but have as well to consider the difference in behaviour between the gases. Helium could be a better replacement for hydrogen than nitrogen, it is however more expensive.
Event Nature
Emergency Action
The hydrogen detectors controlling the closing of the H2 supply valve had not yet been installed. Nevertheless, their absence was not critical thanks to the prompt reaction taken by employees.
Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Release Amount (kg)
30.00
Ignition Source
Detonation
No
Deflagration
No
High Pressure Explosion
No
High Voltage Explosion
No
References
References

Event description in the French database ARIA https://www. aria. developpement-durable. gouv. fr/accident/7518 (accessed October 2020)