Skip to main content

CGH2 cylinders pallets falling from a trailer (596)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

CGH2 cylinders pallets falling from a trailer

On the way home, a trailer/truck overturned due to excessive speed, causing the hydrogen bundles to fall. It was transporting two bundles with 30 cartridges each. One of the bundle valves broke, causing gas to leak and ignite. The fusible valve (thermally activated relief devices) of the bundle also activated. The trailer was returning to the base after delivery, and the cylinders had a residual pressure of approximately of 7 bar.
Event Date
June 27, 1995
Record Quality Indicator
Region / Country
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments

The INITIATING CAUSE was the loss of the load of the trailer. The ROOT CAUSE is usually attributed in a case of road crashes to human error (too high speed). However, the design of the pallets should be able to protect the (safety) valve system, from the type of mechanical impacts expected from a road incident.

Facility Information
Application
CGH2 cylinder trailer
Specific Application Supply Chain Stage
Components Involved
valve (manifold?), TPRD
Storage/Process Medium
Actual Pressure
0
Design Pressure
15
Location Type
Operational Condition
Consequences
Number of Injured Persons
0
Number of Fatalities
0
Event Nature
Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
Detonation
No
Deflagration
No
High Pressure Explosion
No
High Voltage Explosion
No
References
References

High Pressure Gas Accident Cases Database of the KHK (High Pressure Gas Safety Association): https://www. khk. or. jp/public_information/incident_investigation/hpg_incident/incident_db. html (accessed May 2025)

The first entry in HIAD was coming from RISCAD, which is now closed.