An explosion in an electrolyser for the production of chlorine
An explosion occurred in a electrolyser cell, blowing off the cell's vent cover and severing a low-pressure chlorine gas pipeline. , what caused a release of chlorine in the building, The event occurred when two operators were trying to improve the tightness of the diaphragm. They were only very lightly injured. A reaction between hydrogen and chlorine in the cell's headspace was responsible for the explosion. The migration of hydrogen towards the chlorine, producing an explosive mix, was due to excessive pressure in the cathodic compartment.
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments
The INITIATING CAUSE was the diffusion of hydrogen into the chlorine half-cell, creating an explosive mixture. The post-incident analysis revealed a poor quality of the cell's diaphragm: it was part of a batch of diaphragms whose manufacture did not adhere to standard procedures (crosslinking temperature of 275°C instead of 355°C due to a furnace regulation failure) and which subsequently exhibited premature aging.