The event occurred at a hydrogen processing unit of the refinery. A mixture of hydrocarbon and hydrogen leaked ad the 90-debrees-elbow of a carbon steel pipe. The mixture formed a cloud which…

This event occurred at after the testing of a LH2 tank. The LH2 was then removed and the tank purged with helium gas for more than 4 hours. A flange was then removed to allow for insertion of…

An explosion occurred during tensile tests of metals in a liquid hydrogen vessel. efforts were made to prevent air from entering by using a flexible top skirt designed to allow for movement of the…

The accident happened in a low pressure methanol plant, commissioned in summer 1971 . A 6 in. pipe, below the methanol synthesis gas compressor inter-stage relief valve, failed releasing hydrogen…
The reduction stage of the powder production process of a chemical plant had been shut down, and the buffer tank of the line had been drained on the preceding day. After the shutdown, the batch to be…
An explosion occurred in the glass components of a reactor at a pharmaceutical plant during a batch process. At the time of the accident, the reactor was being hydrogenated. As a result of the…
The event occurred at a hydrogen tank (another source reports a 'conduit in an enclosed space') of a hydrogen generation unit of a refinery. The explosion caused a flare and a displacement of air…
A deflagration occurred inside the tank at the start of grinding operations. The tank had contained sulphuric acid. All preparatory procedures had been properly carried out: neutralisation of…
The explosion occurred at the second floor of university building, where a postdoc researcher was conducting a chemical experiment using hydrogen gas in the laboratory. First a chemical fire started…

During general repair and equipment replacement on a liquid oxygen-liquid hydrogen Saturn test facility, a section of the 24-inch GH2 vent line ruptured. An explosion occurred causing extensive…

During welding of a pipe to an existing header vent system, hydrogen gas was ignited. The adjacent vessels and lines were inerted with helium and a hydrogen detection check did not indi­cate…

This incident occurred at a waste water tank of an unspecified chemical plant. An explosive atmosphere formed inside the wastewater tank due to the accidental production of hydrogen. This occurred…

This incident took place at a plant specialised in production of sodium, lithium, and chlorine. A hydrogen explosion occurred during the hydrolysis of sodium residues in a dedicated workshop.…

The explosion was caused by the ignition of hydrogen during reaction with sodium metal. The Chemistry Department routinely dried solvents using metallic sodium. This leaves an excess of sodium metal,…
A release of a mixture of hydrogen, nitrogen and ammonia ignited and exploded in the ammonia synthesis unit. The release was due to a cracked pipe and occurred at the level a flange situated at the…
The event took place in the on one out of the seven reactors for ammonia synthesis. The day of the accident, preparation works for the decennial pneumatic test (previous pneumatic test was carried…
A mechanical failure occurred in a gasification reactor, which caused a violent (abrupt, sudden) depressurisation of the reactor. The consequences were the projection of tiles of the refractory…
Explosion in an electrolyser producing chlorineThe explosion occurred after the opening of an auxiliary circuit-breaker. The opening of the auxiliary circuit breaker trigger the shut down of the…
The explosion occurred in a copper electroplating plant test furnace when starting the operation of copper plating. A tinned copper pipe had been placed inside another copper pipe and lined with…
Works at the power grid of a hydrogen production unit is at the origin of the sequence of the following events: 1. Fusion of a safe fuse triggering the closure of a valve on the manifold of a pistons…