Explosion in a storage tank of a chemical plant
A deflagration occurred inside the tank at the start of grinding operations. The tank had contained sulphuric acid. All preparatory procedures had been properly carried out: neutralisation of residual sludge with carbonate, measurement of oxygen and inflammable gases at various points. The explosion was due to the ignition of approximately 100 g of hydrogen in a dead zone of the tank, which had not been checked with detectors. The hydrogen had been produced by the corrosion of the iron of the tank by the sulphuric acid. The consequences were one dead and 2 severely injured. The tank was partially destroyed.
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments
INITIATING cause is the ignition of undetected hydrogen in a dead zone of the reactor. One contribution cause was probably the incompleteness of operational processes.