Skip to main content

Explosion in a university laboratory (764)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Explosion in a university laboratory

The explosion occurred at the second floor of university building, where a postdoc researcher was conducting a chemical experiment using hydrogen gas in the laboratory. First a chemical fire started in the laboratory, initiated by the tert-butyllithium stored in the lab. The fire involved a compressed hydrogen steel cylinder, 2-3 metre far away. From post-accident investigation, it appeared that the cylinder failed from the bottom, after the explosion only the top half of the cylinder was left intact. This may indicate an explosion initiated by over-pressurisation due to increase temperature. The strong shock wave from the explosion ignited other flammable substances in the laboratory. The windows of the laboratory were blown out, and the balcony guardrails fell off. The outer walls of the neighbouring floors were blackened.
Event Date
December 18, 2015
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments
The INITATING CAUSE was a fire initiated by tert-butyllithium (although the sources do not explain the reason of the start of the fire). The CONTRIBUTING CAUSE was the involvement of a compressed hydrogen bottle in the fire, its explosion, and the further escalation of the fire to other flammable materials. The ROOT CAUSE was the wrong management of hazardous materials (storage, handling). Laboratory safety management was not in place and the students' safety awareness was weak.
Facility Information
Application Type
Application
chemical laboratory
Specific Application Supply Chain Stage
Components Involved
compressed hydrogen cylinder
Storage/Process Medium
Storage/Process Quantity
0
Design Pressure
20
Location Type
Location description
DESCRIPTION OF THE SUBSTANCE INVOLVED tert-Butyllithium: (CH3)3CLi, is an organolithium compound, with applications in organic synthesis. It is a pyrophoric substance, and therefore it would be plausible to assume that the start of the fire was the wrong handling of the substance, which entered in contact with the air.
Operational Condition
Consequences
Number of Injured Persons
0
Number of Fatalities
1
Post-event Summary

One fatality. The windows of the laboratory were damaged in the explosion; iron cabinets and other furnishings in the laboratory were affected due to damaged windows downstairs. Several neighbouring rooms were also affected, with glass broken to varying degrees

Lessons Learned
(i) A proper risk assessment of all laboratory aspects, such a storage and handling of hazardous substances, is critical to reach a minimum level of safety. This is even more important when different typed of hazards are present simultaneously in the laboratory, such as pyrophoric substances which ignite spontaneously in air and flammable, compressed gases. For example, modern laboratory practices do not allow anymore the placement of compressed flammable gases inside the laboratory space. (ii) Safety awareness and the knowledge of the specific risks involved in laboratory experiments is often lacking in students. This could have to do with the limited training and information received, or with the nature of experimental activities, which have seldom a repetitive character and therefore they are difficult to be regulated and standardised in consolidated procedures (SOP = standard operating procedure). Therefore, a constant supervision by more experienced personnel is required, preferably by a permanent lab manager with the required technical competences.
Event Nature
Emergency Action
Teachers and students in and around the building were evacuated; the flame was quickly extinguished; because of the presence of harmful chemicals in the building, the responders measured and detected no harmful gases on the scene two hours after the explosion.
Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Detonation
No
Deflagration
No
High Pressure Explosion
No
High Voltage Explosion
No
References
References

"BAIDU" news page: https://baike. baidu. com/item/12. 18%E6%B8%85%E5%8D%8E%E5%A4%A7%E5%AD%A6%E4%B8%80%E5%AE%9E%E9%AA%8C%E5%AE%A4%E7%88%86%E7%82%B8%E4%BA%8B%E4%BB%B6/19158066 (accessed August 2024)

Machine translation of the reference

L. Guo et al. , Hydrogen safety: An obstacle that must be overcome on the road towards future hydrogen economy, Int. J. Hydrogen Energy, 2024, https://doi. org/10. 1016/j. ijhydene. 2023. 08. 248