HIAD Nature Event - Ignition Source: Open Flame - Burner, Torch, Etc.


Early in the morning a hydrogen tube trailer experienced a tire fire and pulled onto the road shoulder. The driver attempted to extinguish the fire with the fire extinguisher on the vehicle. Heat…

The trailer experienced a tire/wheel fire at the rear of the tube trailer. The fire deteriorated the hand valve packing on one of the tube causing a slow leak of hydrogen. The trailer consisted of…

On a cold morning, the gasoil hydro-treatment unit was being brought back on line after being out of service to repair a governor problem on the recycle gas compressor. Several upset trips had…
An explosion at a refinery happened inside a hydrogen heater when a hydrogen line ruptured.
The incident occurred at an indirect oil desulphurisation unit, and originated on a piping at the outlet of a heat exchanger. The exchanger was located in the furthermost downstream of the reactor.…
The accident occurred during the maintenance of a sulphuric acid storage tank in an industry for the fertilizers production. The maintenance works consisted in cutting operations (to remove some…
Workers were performing demolition on a disused furnace. While removing a 10 inch valve from a pipe used to supply coke gas fuel to the furnace, flammable liquid was unexpectedly released and ignited…
The explosion occurred at the second floor of university building, where a postdoc researcher was conducting a chemical experiment using hydrogen gas in the laboratory. First a chemical fire started…

During general repair and equipment replacement on a liquid oxygen-liquid hydrogen Saturn test facility, a section of the 24-inch GH2 vent line ruptured. An explosion occurred causing extensive…

An explosion and fire occurred in a mud logging unit during the final phase of rigging it up. Gas analysers had been calibrated and the flame ionization detection (FID) and total hydrocarbon analyser…
An explosion occurred in the teat treatment workshop of this site. The explosion was centred in the electrical control panel of the High Velocity Oxy Fuel (HVOF) thermal spraying equipment. The…

An explosion involving several entertainment balloons filled with hydrogen. The balloons were used as props at a public sport event for children. The explosion caused light injuries to 16 persons.…

The last flight of the Space Shuttle Challenger ended 73 seconds after the launch in an explosive burn of hydrogen and oxygen propellants that destroyed the External Tank and exposed the Orbiter to…
The accident occurred when a welder belong to a sub-contractor company was working on tank roof. The zeolite crystallisation tank was being cleaned out with approx. 20% sulphuric acid. It was not…

[Note HIAD validator: this an incident where the hydrogen systems were invovled as effects of the initiating event. There is nevertheless and addtional possible contribution by hydrogen…

A common vent system was used to connect vent lines from liquid hydrogen storage vessels to the vent stack (which was lit flaring the gas). Low order detonations were observed around the vent…

At a rocket engine testing facility, a combustion experiment of the pre-burner (gas generator for driving the turbopump) was being conducted, before testing the turbopump. The pre-burner is the…

The incident occurred in the fired heater of a hydrocracking unit. Due to overheating, about 250,000 pounds of hydrogen and naphtha mixture were accidentally released into the firebox of the fired…

This incident occurred at the fired heater of a non-further specified reactor of a refinery (probably a hydro-desulphurisation unit). A tube of the fired box failed releasing a mixture of hydrogen…

When waste alkali solution was taken out of dumper trucks into a waste liquid storage tank, a reaction occurred in the tank. As a result, the solution in the tank foamed over it, and reached an…