Explosion in coating spray equipment (300)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Explosion in coating spray equipment

An explosion occurred in the teat treatment workshop of this site. The explosion was centred in the electrical control panel of the High Velocity Oxy Fuel (HVOF) thermal spraying equipment. The violent explosion propelled shrapnel, killing one person present. Four further personnel were injured. The hydrogen, leaked from a loose connection on the flashback arrestor of the unit, then migrated into the upper compartment of the HVOF console. At the point, an explosion when the hydrogen was ignited by a spark from any one of the electrical switches or relays contained there. The leaking connection was on a component which in all probability had only just been replaced. It is probable that the new arrestor, tightened the connections by hand and intended to tighten them with a spanner later but forgot to do so. Two recently drilled holes in the barrier partition of the HVOF console provided a potential leakage path for hydrogen into the electrical cabinet. Purge air which is intended to pressurise the electrical cabinet to prevent flammable gas ingress was not connected at the time of the explosion. The hydrogen pipework had not been leak tested prior to recommissioning. Safety systems to prevent flammable gas ingress into the electrical cabinet had been disconnected or bypassed.
Event Date
April 24, 1998
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments
The INITATING CAUSE was a loose hydrogen connection, probably due to the fact that it had not been tightened when replacing the connection. The ROOT CAUSES were a combination of lack of safety measures, shortcoming in the existing procedure and modification to the facility without executing a new risk assessment.
Facility Information
Application Type
Application
Coating production
Specific Application Supply Chain Stage
Components Involved
High Velocity Oxy Fuel (HVOF) spray machine.
Storage/Process Medium
Location Type
Location description
DESCRIPTION OF THE FACILITY A high velocity oxy-fuel spray machine (HVOF) is a thermal spray processes using a mixture of a gaseous fuel and oxygen. The gas can be hydrogen, methane, propane, propylene, acetylene, natural gas, etc. The mixture is fed into a combustion chamber, where it is ignited and combusted continuously. The resultant hot gas at a pressure close to 1 MPa emanates through a converging-diverging nozzle and travels through a straight section.
Operational Condition
Pre-event Summary
Under normal operation, the upper compartment of the HVOF console would have been supplied with purge air and any holes in the central dividing panel would have been sealed by the presence of valves and other components. The purge air was not connected. Under normal circumstances, the lack of purge air pressure and open door would prevent the unit from operating. However, these two safety devices were observed to have been bypassed.
Consequences
Number of Injured Persons
4
Number of Fatalities
1
Investigation Comments

According to the investigation, the hydrogen, having leaked from the loose connections on the flashback arrestor of the unit, migrated into the upper compartment of the HVOF console. An explosion then occurred when it was ignited by a spark from any one of the electrical switches or relays contained there. The leaking connection was on a component which in all probability had only just been replaced. It is probable that the new arrestor, tightened the connections by hand and intended to tighten them with a spanner later but forgot to do so. Two recently drilled holes in the barrier partition of the HVOF console provided a potential leakage path for hydrogen into the electrical cabinet. Purge air which is intended to pressurise the electrical cabinet to prevent flammable gas ingress was not connected at the time of the explosion. The hydrogen pipework had not been leak tested prior to recommissioning. Safety systems to prevent flammable gas ingress into the electrical cabinet had been disconnected or bypassed.

Lessons Learned
Conclusions of the investigation: 1. The hydrogen pipework had not been leak tested prior to recommissioning. 2. Safety systems to prevent flammable gas ingress into the electrical cabinet had been disconnected or bypassed.
Event Nature
Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Detonation
No
Deflagration
No
High Pressure Explosion
No
High Voltage Explosion
No
References
References

Event description provided by HSE, original source confidential