Conventional fire on a CGH2 trailer (1139)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Conventional fire on a CGH2 trailer

Early in the morning a hydrogen tube trailer experienced a tire fire and pulled onto the road shoulder. The driver attempted to extinguish the fire with the fire extinguisher on the vehicle. Heat from the fire caused seats on the isolation valves of two tubes to deform and the welded stainless steel manifold to crack, releasing hydrogen, ignited then by the tire fire. The driver was unable to extinguish the fire and called the emergency number. Emergency responders closed the highway in both directions for several hours. There were 2 injuries, the material damage was limited to the trailer.

Event Date
February 12, 2011
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments

The INITIATING CAUSE was a conventional fire on tire following brake failure. The ROOT CAUSE can be probably related to ageing of the tires or of the brake system. Maintenance procedures are in palce to avoid these azards. Morevoer, tube protection from conventional fires seems having been not very effective (design shortcoming).

Facility Information
Application
CGH2 tube trailer
Specific Application Supply Chain Stage
Components Involved

tire, Piping, Fittings

Storage/Process Medium
Storage/Process Quantity
279
Actual Pressure
18
Design Pressure
18
Location Type
Operational Condition
Pre-event Summary

The incident started wit haconcentional fire on tires. The trailer was carrying 10 tubes, only two of them were affected by the tyres fire.

Consequences
Number of Injured Persons
0
Number of Fatalities
0
Environmental Damage
0
Currency
Property Loss (onsite)

131000

Property Loss (offsite)

0

Post-event Summary

no fatalities, no injuries, and damage was limited to the trailer

Lessons Learned

The conventional brake fire which started this incident did not produce a heat input to the CGH2 tubes to cause their internal pressure to raise above the limit set by the pressure relief system. The burst disc did not open. The only damage caused by the fire was to a seal fitting, which caused a leak with limited consequences. Nevertheless, other cases started with conventional fires caused the venting of the whole hydrogen load, because the pressure relief valve were thermally or pressure-activated. Such a scenario has to be avoided when the trailers are in a confined space, such as a tunnel.

Event Nature
Emergency Action

The driver tried to extinguish the fire by means of the extinguisher available on-board. Sine he did not succeed, the driver called the emergency responders which closed the highway in both directions for several hours. The strategy adopted in regard of the fire is unknown.

Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
References
References

Incident I-2011060207 of the US Pipeline and Hazardous Materials Safety Administration PHMSA: https://portal. phmsa. dot. gov/analytics/saw. dll?Portalpages&PortalPath=%2Fshared%2FPublic%20Website%20Pages%2F_portal%2FHazmat%20Incident%20Report%20Search (accessed September 2024)