Explosion on a storage vessel of a chemical plant (306)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Explosion on a storage vessel of a chemical plant

The accident occurred when a welder belong to a sub-contractor company was working on tank roof. The zeolite crystallisation tank was being cleaned out with approx. 20% sulphuric acid. It was not pressurised and was vented to atmosphere. The worker had been asked to cut a larger inspection hole in tank top. He had not yet begun to cut, but possibly had already lit up the oxy-acetylene equipment, when a loud explosion was heard by many. Hydrogen evolution due to acid action on steel vessel walls was suspected to be the cause of the accident.
Event Date
November 18, 1996
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments
The HSE communication does not give indications useful for drawing a root cause.
Facility Information
Application Type
Application
Chemical storage
Specific Application Supply Chain Stage
Components Involved
zeolite crystallisation tank
Storage/Process Medium
Location Type
Operational Condition
Pre-event Summary
The accident occurred when the tank was being cleaned. An additional intervention was planned, consisting in cutting a large inspection hole on the tank top. .
Consequences
Number of Injured Persons
0
Number of Fatalities
1
Investigation Comments

1. Oxy acetylene equipment and sample from tank taken for analysis. 2. FCG contacted. 3. Hydrogen evolution due to acid action on steel vessel walls suspected to be the cause of the accident.

Event Nature
Release Type
Release Substance
H2 (probably)
Hydrogen Release Concentration (%)
0.00
Detonation
No
Deflagration
No
High Pressure Explosion
No
High Voltage Explosion
No
References
References

Event description provided by HSE, original source confidential