Release from a hydrogen truck (1055)
This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.
Release from a hydrogen truck
A hydrogen leak took place on a trailer carrying compressed hydrogen, located inside the fenced perimeter of a hydrogen station. According to the company managing the hydrogen delivery and refuelling station, the leak did not pose any risk to people or the environment. A preliminary assessment identified a faulty valve source of the leak, but it was unclear at that time if it was a single defect or a systemic (i. e. design) problem. Following a detailed investigation in close cooperation with the trailer and valve suppliers, the company determined that the root cause of the valve malfunction was due to a set of improperly tightened bolts, causing an O-ring to burst. Approximately one month later, addtional malfunctioning were found on the same valves on othr eight trailers.
The INITIATING CAUSE The was a non-further specified defective valve. The assembly error was not detected by valve supplier quality control nor by the tube trailer suppliers’ quality inspection, but only when the all assembly was operating. This, and the fact that more valves were found defective, suggest as ROOT CAUSE an improper tightening procedure damaging the O-ring , an installation error or a manufacturing defect.
We are professional and reliable provider since we offer customers the most powerful and beautiful themes. Besides, we always catch the latest technology and adapt to follow world’s new trends to deliver the best themes to the market.
Contact info
We are the leaders in the building industries and factories. We're word wide. We never give up on the challenges.