release at a hydrocracker in a refinery plant
The event affected the hydrocracker unit. A sudden release into a cracker compressor flare header destroyed a safety relief valve and damaged a sight glass on a liquid collection pot. As a consequence, release of hydrogen rich vapour to atmosphere occurred, necessitating a shut down of the iso-cracker. The damage was limited to that previously described, and there were no injuries. The cracker was returned to service four days later.
Event Date
December 21, 1991
Record Quality Indicator
Region / Country
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments
According to the ICHEME report (see reference), the INITIATING cause was an accumulation of liquid in the flare header. The problem was compounded by undersized header and piping, and triggered by unstable operating conditions. Considering the recommendations reported by the ICHEME report, it could be concluded that contributing or root causes were inadequacy of related design and of procedures.