Skip to main content

Release from a hydrogen bus (880)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Release from a hydrogen bus

A hydrogen and fuel cells bus experienced a hydrogen detection alarm in a city centre. This triggered the evacuation of the immediate surroundings and the towing of the vehicle to the maintenance garage.
Event Date
July 30, 2018
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes
Facility Information
Application Type
Application
Hydrogen bus
Specific Application Supply Chain Stage
Storage/Process Medium
Location Type
Operational Condition
Consequences
Number of Injured Persons
0
Number of Fatalities
0
Post-event Summary

The actions and corrective measures taken by the the bus manufacturer after the alarm are indicative of the long pathway still necessary before arriving to full deployment maturity of hydrogn-based mobility solutions. A. Collected the vehicle (VH VIN 66242) from the city Depot B. Review and analysis of the gydrogen exhaust set-up and the fuel cell cooling systm C. Re-built the bus to original set-up triggering fault/alarm D. Installed measurement equipment (8 H2 concentration sensors) to measure hydrogen concentration in exhaust and under roof panels. E. Installated 2 extra sensors to determine if the normal sensors (8) do not react to other gasses but only to hydrogen F. Installed of additional dataloggers, for extra datalogging and evaluation of principalsystem. G. Mapped the hydrogen flow via visualization of gas H. Modifiedy the vehicle to resolve issues with high hydrogen concentration if necessary. I. Brought vehicle back to the city and performed a thorough test on route to determine that sensors do not pick up any other gas concentrations that can trigger warning or alarm. K. Modified the 2nd bus accordingly

Lessons Learned
It is important to use hydrogen sensors and detectors characterised by low cross-sensitivity to other gases. In this way, the risk of false alarm triggered by the presence of other gases is minimised. The accuracy, the alarm level and the location of the sensors are also relevant.
Event Nature
Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
Detonation
No
Deflagration
No
High Pressure Explosion
No
High Voltage Explosion
No
References
References

Report provided but confidential