An explosion occurred around noon while conducting hot work (with a disc saw) on a 320-m³ fixed-roof tank at a pharmaceutical plant employing 240 personnel. The tank belongs to a waste treatment unit…
A release of a mixture of hydrogen, nitrogen and ammonia ignited and exploded in the ammonia synthesis unit. The release was due to a cracked pipe and occurred at the level a flange situated at the…
The event occurred at the hydrogen production unit of the ammonia production plant. An air-hydrogen mixture formed in the building hosting a water pump which fed water to a vessel that contained…
An explosion and fire occurred in a mud logging unit during the final phase of rigging it up. Gas analysers had been calibrated and the flame ionization detection (FID) and total hydrocarbon analyser…
Hydrogen was accidentally produced inside the sealed container containing a used battery. The gas, along 6 days deformed the container. Firefighters equipped with breathing apparatus opened the…

An internal explosion occurred in a cone-roof gas oil tank. The explosion completely ruptured the weak roof-to-shell weld seam and projected the roof into the diked area beside the tank. The…

The Microbiological Anaerobic Chamber of approximately 2 m3 capacity was containing an explosive mixture of hydrogen and air. A fire followed the explosion, but was rapidly extinguished by staff…
The accident occurred during the night during the production of a silicon oil- and additive-based waterproofing agent. A junior technician (hired 6 months back), recently assigned to this post, was…
The incident occurred in a catalytic reforming unit. At 13:41, a leak occurred at the 90° elbow of a pressure pipe containing a mixture of hydrogen and naphtha. This pipe was located between the pre…
The event started at the effluent pipe of one of the hydro-cracking reactors, which broke and released a mixture of hydrogen, light gases (methane, butane), light gasoline; heavy gasoline; gas oil.…
A section of effluent piping ruptured on the hydrocracker reactor of a refinery. A mixture of light gases (methane, butane), light and heavy gasoline, gas oil and hydrogen was released from the pipe…

The incident occurred at a heat exchanger involving gas-product mixture. The source does not specify the process, with as main component a furnace, probably a hydrodesulphurisation reactor. Due to…

The loss of control of a reaction caused a fire in a pharmaceutical plant caused a reaction runaway and the rupture of a 6 m³ reactor. A cloud containing sodium borohydride and hydrogen was emitted.…

A compressed hydrogen container was being filled at a refuelling station. The container was belonging to trailer and consisted in a bundle of tubes connected via piping to a manifold and filling…

An explosion occurred in a nitrogen wash cold box (outside the equipment) after a several day cold shutdown followed by a derime with nitrogen. It is assumed that ice may have split tubes…

The incident occurred at the hydrofining unit, refining a mixture of petroleum and diesel into Euro 3 and Euro 4 diesel. A pump feeding the reactor with the process mixture failed. Following the…

An explosion occurred in hydrogen compressor, followed by a fire, due to rupture of 4 inch suction pipe to the compressor. "there was a substantial release of hydrogen, which exploded and continued…

A hydrogen-air explosion occurred outside a hydrogen compressor. Gaseous hydrogen was released from the vent stack due to a premature activation of a relief valve. The flammable atmosphere ignited…

An explosion occurred at a hydrogen compressor of a polysilicon plant. The head of the compressor was blown off and the released hydrogen exploded causing extensive damage to the building and to…

An explosion of hydrogen gas occurred on a test bench at a factory manufacturing rocket engins. The effect was perceived several kilometres away. The explosion was caused by the release of 8 kg of…