HIAD Nature of the Consequences: Explosion followed by a fire


The incident occurred in the hydrogenation unit of a non-further specified chemical plant (SEVESO facility). The hydrogenation unit was probably part of the phenols processing. Before the occurring…
An explosion followed by a fire occurred at a tar precipitator of gas treatment of a coke oven. The extractors were manually activated. Ten minutes later, the operator activates the internal…
At the time of the incident, the desulphurisation unit was shut down for scheduled cleaning of a cooling tower with reintroduction of a gas mixture into the system at a high hydrogen content. The…
The event occurred at an ethylene production plant. The plant was shutdown at the time as the supply of compressed air to the gauges had inadvertently been switched off. This failure of the air…
A violent explosion occurred at a blast furnace. The explosion occurred while the blast furnace was being cleaned at the end of casting. For this purpose, worker poured the contents of a casting…

[Note of the event validator: according to the sources, hydrogen as combustible gas does not seems to have plaid part in this incident. However, it is more plausible that hydrogen, as the main…

The explosion occurred at the premises of a manufacturer of special gases. A hydrogen trailer in the trailer parking lot had leaked hydrogen, which then ignited. The explosion was clearly audible…

An explosion or fire occurred in a hydro-treatment unit which was processing Fluid Catalytic Cracking feedstock. It was caused by a failure in a pipe downstream from a separator, resulting in the…
On a cold morning, the gasoil hydro-treatment unit was being brought back on line after being out of service to repair a governor problem on the recycle gas compressor. Several upset trips had…
Five workers were in the process of trouble shooting a hydrogen compressor. No actual work was in process, but the compressor had still hydrogen in the lines. The three were only listening for…

An explosion occurred in a hydrogen storage tank followed by fire.

A gas mixture (25% nitrogen, 73% of hydrogen, 2% methane) leaked, due to the ejection of the check valve from its connection with the inlet pipe. A large amount of the gas mixed with air and ignited,…
An explosion occurred at a aerospace testing centre, while testing a liquid hydrogen turbo-pump, part of a rocket engine. On the day of the incident, seven seconds after the rotation speed of the…
An explosion and fire occurred at a chemical plant applying silicone coatings. The blast occurred when some polymethyl hydrogen siloxane was accidentally fed into a reactor, together with the correct…
The incident occurred at an indirect oil desulphurisation unit, and originated on a piping at the outlet of a heat exchanger. The exchanger was located in the furthermost downstream of the reactor.…
A fire and explosion occurred at a catalytic reformer unit. The fire centred between the reactors and fired heaters of the reformer and resulted in extensive damage to the unit. The explosion rocked…
The accident occurred in the hydro-cracking unit, specifically in its sulphur recuperating system. The location was on a 8" piping, which cracked at a a 90° bend. Due to the loss of confinment, a…
The accident started with a leakage of distilled petroleum intermediate and hydrogen in the desulphurization unit of the distilled intermediate. Both substances ignited and exploded, with a later…

The incident occurred "in the near of a hydrogen compressor" and consisted first in an explosion, followed by a fire. Cause not disclosed. Emergency control and mitigation actions…

A hydrogen explosion occurred at the hydrogen storage unit of a power generation plant. A burst disc opened, releasing approximately 3 tons of hydrogen. The leaked hydrogen formed an explosive…