Explosion at a hydrogen compressor
Five workers were in the process of trouble shooting a hydrogen compressor. No actual work was in process, but the compressor had still hydrogen in the lines. The three were only listening for obvious noises which would help diagnose the problem. A common 4" line ruptured, releasing hydrogen to the atmosphere, resulting in an explosion and a fire. 3 fatalities and 2 injuries.
Event Date
December 5, 1985
Record Quality Indicator
Region / Country
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments
The INITIATING cause was the loss of confinement of a hydrogen line. Two 'operators' had just brought the compressors for repair to 'machinists'. It is unknown if this was the common practice, but the fact that the hydrogen compressor had not purged as first operation hints at shortcoming in the safety measures.