While preparations were being made for a LH2 turbopump test, an explosion occurred above the test cell. Major damage was caused throughout the test facility. A short duration fire caused minor…

The event started when a gasket in a water pump was blown out. The water pump was situated inside a 100 m long, 10 m wide, and 7 m high building. The pump was feeding water to a vessel containing…
An explosion, accompanied by abundant black smoke, occurred at an ammonia production plant. An ignited leak of hydrogen in the ammonia production unit had spread to the pressure circuit carrying…
The explosion followed a hydrogen leak on a unit conditioning hydrogen. The leak was caused by the mechanical rupture of the membrane of a pressure release device which was part of a pressure…

[Note HIAD validator: this an incident where the hydrogen systems were invovled as effects of the initiating event. There is nevertheless and addtional possible contribution by hydrogen…

Several explosions occurred in one of the catalytic reforming units of the refinery, followed by a fire in the same unit. The fire derived from the explosions lasted for almost one day. The…

A series of explosions occurred in thee desulphurisation and catalytic reforming unit of the refinery, followed by fires in the same unit. The establishment is classified as Seveso Upper Tier…

The accident occurred in the Reactor 6 used to carry out the hydrogenation of a pharmaceutical intermediate. The operation of the plant was organized in two shifts. Since the hydrogenation at Reactor…

The incident occurred when filling a gaseous tube trailer from a liquid hydrogen stationary storage system. The liquid hydrogen cryogenic pump shaft malfunctioning caused a series of explosions…

Workers were connecting a compressed hydrogen cylinder, when a release of hydrogen occurred within a safety-box for flammable gases (a safety cabinet). During the emergency response procedures, the…
The failure of a high pressure hydrogen-based synthetic gas feed line to the ammonia converter produced a sudden explosion followed by a severe fire. One of the operators was fatally injured. The…

The incident occurred during the filling of six bundles of compressed hydrogen cylinders by means of a compressor. Each bundle consisted of 16 cylinders of 40-liter each. When approaching the…

The explosion and fire happened in a diesel hydro-treatment unit used to desulphurise raw diesel be means of hydrogen. The facility was expected to begin full commercial operations later in 2020.
There was a massive explosion at one of the generator-turbine units of a coal-based power station. Undetected hydrogen leak from the generator was identified as a major trigger. According to the news…
A hydrogen leak occurred on the a coolant pipe of an electrical generator located in the turbine building, at 200 m from the reactor. Because of the welding works ongoing at that moment on the pipe,…
SYNOPTICs The loss of the hydrogen side sealing oil pump and other problems in the sealing oil system resulted in the coolant hydrogen leaking from the generator. The hydrogen leaked for several…
Explosion and fire in gasholder storing hydrogen in a thermal black plant
This incident occurred in a unit processing vegetable oils and fats. the explosion occurred in a hydrogenation facility, specifically where hydrogen is processed with a very high-pressure (400 bar).…
First an explosion and then a fire occurred on the condensate piping of an chlorine electrolysis plant (SEVESO upper tiers). Flames escape from the end of the pipe and spill into a 75 m³ open sky…

An explosion of a mixture of hydrogen and hydrocarbons occurred at a fired heater of a refinery. A mixture of a hydrogen and hydrocarbon mixture was accidentally released into the firebox of a…