HIAD Nature of the Consequences: Explosion followed by a fire


The accident occurred in a plant producing synthesised active ingredients for the pharmaceutical industry. An explosion and a fire occurred in one of the workshops of the plant. The chemical reaction…
An explosion followed by a fire occurs in a refinery, originated by a hydrogen release at the hydrogen compressor.
A 24" pipe carrying synthesis gas (Hydrogen = 43. 5%, Nitrogen = 14. 08%, Methane = 0. 2%, Carbon Dioxide = 12. 3%, Water = 29. 3% by volume) ruptured. About 60 kg of hydrogen contained in the gas…
A fire started as a result of an explosion in the process section of a refinery. An open structure of steelwork protected with reinforced concrete housed the usual furnaces, reactors, heat exchangers…
Hydrogen was released into a diesel desulfurization unit, producing a 50-meter-long horizontal torch flame upon ignition. The unit was operating normally. Refinery firefighters responded quickly and…

A truck loaded with 400 hydrogen bottles crashed into a concrete barrier and tipped over. After tipping over, the vehicle slid about 150 meters across the road. The hydrogen was released, ignited…

The incident occurred in a workshop of a bus company. Hydrogen leaked from a tank on a new hydrogen and fuel cell bus parked there. The cause of the leak is unknown. From conversations with the…

At a chemical processing plant, a release of pressurised hydrogen gas resulted in an explosion and fire injuring lightly three workers and causing damage to plant. The incident occurred during the…

The incident occurred at the hydrocracker unit of a refinery. A mixture of hydrogen and hydrocarbon gas was accidentally released. The flammable gas formed a vapour cloud that ignited, resulting…

The incident occurred while transferring gaseous hydrogen from a tube trailer to a customer stationary supply system. The transfer hose ruptured and released hydrogen which ignited explosively.…

The incident occurred at a reactor vessel of a naphtha hydrotreater unit. The vessel operated at around 25 bar and 140 C. A 1. 5-meter crack opened up in the reactor vessel close to welded vessel…

An explosion and fire occurred at a reciprocating recycle hydrogen compressor during commissioning of a new Diesel hydrotreatement Unit. It happened during the reactor pre-sulphidisation step, when…

hydrogen gas cylinder explosion and subsequent fire in an electrical products company. 3 fatalities and 8 injuries. [Note of the validator: while the majority of the news report as cause the…

The accident occurred at a distillate dewaxing Unit (MDDW) of the refinery, during the operation of regeneration of the catalyst. To perform this operation, both temperature and pressure have to be…

A hydrogen gas explosion occurred at the hydro-treating unit of a renewable diesel plant. The explosion was followed by a fire which was extinguished an hour later by the local resources. Two…

An explosion took place at the hydrodesulphurisation unit of a refinery's crude oil. A leak occurred on suction line of a hydrogen compressor used for the re-circulation of the hydrogen required for…

The incident occurred at a plant manufacturing polymer batteries, audio and GPS systems. As consequence of the great tohokyu earthquake and tsunami, a pipe of a hydrogen tank started leaking,…

A series of explosions at an oil refinery reformer unit caused by a rupture to an 8 inch naphtha and hydrogen feed pipe. Fire officials cited higher than normal line pressures just before the blast.…
The fire broke out on a worm ("vis sans fin") supplying a conveyor of aluminium. The ignition of the powder on the ground was caused by the flame cutting operation on the worm shell which generated…
A leak of a flammable mixture of hydrocarbons and hydrogen from a ruptured pipeline caused an explosion and fire, killing one person and injuring forty six. Investigations into the incident found…