Explosion and fire in chemical plant (218)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Explosion and fire in chemical plant

The incident occurred in the hydrogenation unit of a non-further specified chemical plant (SEVESO facility). The hydrogenation unit was probably part of the phenols processing. Before the occurring of the event, a growing leak had been discovered in the vicinity of a circulation pump. The pump was switched off and a routine tightening operation of the stuffing box packing was executed. During the switching on again of the circulation pump, a loss of containment of the circulated fluid occurred, consisting (see eMARS source) in p-tert-butylcyclohexanol p-tert-butylphenol and hydrogen. The fluid ignited, resulting first in an explosion and a subsequent fire. DETAILS OF THE ACCIDENTAL SEQUENCE To restart the circulation pump, one employee remained at pump site at while another went to the control room to adjust the pump's flow rate. When switching on the pump, an abrupt depressurisation via the pump took place. This was only possible because the double shut-off valves on the suction side of the pump were open and the intermediate pressure-reducer was closed. The circulation pump was thus subjected to a system pressure of approximately 300 bar. The pressure sleeve, the stuffing box packing rings, and other associated parts were forced out at this pressure, with consequent release of the fluid. The employee at the pump was wetted by the released substance and ran to the emergency shower. The employee in the control room noticed smoke coming from the pumping area and activated the off switches for the hydrogen supply valves and the pumps. Shortly afterwards, there was a loud bang, and following the bang, a fire broke out. The plant fire department was immediately alerted and extinguished the fire.
Event Date
July 26, 1997
Record Quality Indicator
Region / Country
Classification of the Physical Effects
Nature of the Consequences
Cause Comments
INITIATING CAUSE was the re-start of the operation with the wrong set of valves parameters. ROOT or contributing CAUSE was the lack of training/experience of the workers involved. Although not mentioned by the sources, a root or contributing CAUSE was very probably the absence or inadequacy of operative procedures for the specific action executed.
Facility Information
Application Type
Application
hydrogenation reactor
Specific Application Supply Chain Stage
Components Involved
high pressure hydrogenation reactor, circulation pump, double gate valve
Storage/Process Medium
Location Type
Location description
DESCRIPTION OF THE PROCESS The hydrogenation unit treated p-tert-butylcyclohexanol ( (CH3)3CC6H10OH) and p-tert-butylphenol ((CH3)3CC6H4OH).
Operational Condition
Pre-event Summary
The accident at the restart of the circulation pump, following maintenance works due to leakage.
Consequences
Number of Injured Persons
4
Number of Fatalities
0
Currency
Property Loss (onsite)
1000000
Property Loss (offsite)
25000
Post-event Summary

One staff member was injured by the released hot melt, two staff members suffered shock, and another one broke his foot while climbing down a ladder after the detonation. Costs amount to ca. 1. 000. 000 EURO inside the premises and 250. 000 outside.

Lessons Learned
Although not mentioned by the sources, this is a case where an automatic control system could have avoid the wrong choice of valves setting.
Event Nature
Emergency Action
The circuit breakers of the hydrogen feed valves and the pump valves were actuated. The on-site emergency response service was immediately alerted and extinguished the fire.
Release Type
Release Substance
H2, Phenols
Hydrogen Release Concentration (%)
0.00
Release Pressure (bar)
300.00
Ignition Source
Detonation
No
Deflagration
No
High Pressure Explosion
No
High Voltage Explosion
No
Flame Type
References
References

Event description in European database eMARS https://emars. jrc. ec. europa. eu/en/emars/accident/view/e0bda8c2-77e3-ba7b-8010-02a8fb685576 (accessed September 2020)

Event description in French database ARIA https://www. aria. developpement-durable. gouv. fr/accident/14779/ (accessed September 2020)

Event from German database ZEMA https://www. infosis. uba. de/index. php/de/site/2854/zema/index/2983. html (accessed December 2024)