HIAD Causes: Management Factors


A compressed hydrogen container was being filled at a refuelling station. The container was belonging to trailer and consisted in a bundle of tubes connected via piping to a manifold and filling…

A hydrogen-air explosion occurred outside a hydrogen compressor. Gaseous hydrogen was released from the vent stack due to a premature activation of a relief valve. The flammable atmosphere ignited…

A hydrogen compressor had been shut down for repairs and was being put back into service when the explosion occurred, causing damage . The compressor was equipped with interchangeable in­ take and…

The incident involved an hydrogen-on-demand unit (HOD), which was installed inside an environmental test chamber used for reliability tests. An employee was troubleshooting the chamber, assessing the…
The accident occurred when a welder belong to a sub-contractor company was working on tank roof. The zeolite crystallisation tank was being cleaned out with approx. 20% sulphuric acid. It was not…
The event started when a gasket in a water pump was blown out. The water pump was situated inside a 100 m long, 10 m wide, and 7 m high building. The pump was feeding water to a vessel containing…
The release and fire occurred during what appeared to be a normal operation in a reactor section of a Residue Hydrotreater Unit, when an eight-inch pipe connected to a heat exchanger failed at the…
A process operator was working on a hydrogen tank in a mechanical workshop. The goal of the onoging operation was the removal of the collar from a hydrogen cylinder. An electric crosscut saw was used…

A series of explosions occurred in thee desulphurisation and catalytic reforming unit of the refinery, followed by fires in the same unit. The establishment is classified as Seveso Upper Tier…

A common vent system was used to connect vent lines from liquid hydrogen storage vessels to the vent stack (which was lit flaring the gas). Low order detonations were observed around the vent…

Two hydrogen explosions occurred at a boiling water reactor (BWR). The first explosion occurred at 9:30 a. m. and was mostly confined to the off-gas system. Damage was relatively minor. The second…
The accident occurred in the Reactor 6 used to carry out the hydrogenation of a pharmaceutical intermediate. The operation of the plant was organized in two shifts. Since the hydrogenation at Reactor…

During a test of an 8 foot scale tank loaded with LH2, the tank burst at 77 psi (ca. 5. 3 bar) destroying the test installation. No fire or explosion occurred and the area control was successfully…

The incident occurred during the filling of six bundles of compressed hydrogen cylinders by means of a compressor. Each bundle consisted of 16 cylinders of 40-liter each. When approaching the…

This incident occurred at an aromatics manufacturing plant. A staff member patrolling the plant heard a strange noise and rushed to the site, where he discovered a hole in a pipe, from which hydrogen…
The process unit affected by the incident was a two-step production, consisting of i) hydrogenation of phenyl acetyl carbinol with benzyl amine in a isopropyl alcohol/water mixture by means of a…

A hydrogen leak occurred at the connection between a temperature measuring sleeve and a flange on the cleaning tower of a fertilizers plant (approximately 70% hydrogen, 21% nitrogen and the rest…

This incident occurred at the fired heater of a non-further specified reactor of a refinery (probably a hydro-desulphurisation unit). A tube of the fired box failed releasing a mixture of hydrogen…

The incident occurred at the hydrogen coolant circuit, when purging the hydrogen with carbon dioxide and air, aiming at finding a leak. Following a preliminary investigation, the power plant company…
There was a massive explosion at one of the generator-turbine units of a coal-based power station. Undetected hydrogen leak from the generator was identified as a major trigger. According to the news…