Explosion on a hydrogen compressor a space centre

A hydrogen compressor had been shut down for repairs and was being put back into service when the explosion occurred, causing damage . The compressor was equipped with interchangeable in­ take and outlet valves, which had been exchanged during re-installation. [Ordin, NASA (1974)]

Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments

The discharge valve was installed in the intake position causing the cylinder head to blow off and release hydrogen to the atmosphere. Source of ignition unknown. A CONTRIBUTION CAUSE could be related to a wrong execution of a maintenance/repair step. However, the fact that the two valves could be exchanged calls for a ROOT CAUSE on inadequate procedures and risk assessment.

Facility Information
Application Type
Application
Aerospace
Specific Application Supply Chain Stage
Components Involved

compressors, valves

Storage/Process Medium
Location Type
Operational Condition
Consequences
Number of Injured Persons
0
Number of Fatalities
0
Lessons Learned

The event highlighted the importance of correct labelling, error-proof connections and accurate installation/repair instructions. The lack of these elements is a sign of an inadequate risk assessment.

Event Nature
Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
References
References

Mishap no 60 in P. L. Ordin, Review of hydrogen accidents and incidents in NASA operations, 1974, NASA TM X-71565 https://ntrs. nasa. gov/citations/19740020344

Lowesmith et al. , Safety issues of the liquefaction, storage and transportation of liquid hydrogen: An analysis of incidents and HAZIDS, Int. J. Hydrogen energy (2014) https://doi. org/10. 1016/j. ijhydene. 2014. 08. 002

Hankinson and Lowesmith, Qualitative Risk Assessment of Hydrogen Liquefaction, Storage and Transportation, FCH JU project IDEALHY, Deliverable 3. 10 (2013) confidential (accessed October 2025)

Also uploaded by H2TOOLS https://h2tools. org/lessons/discharge-valve-installation-error (accessed Decembr 2025)