HIAD Causes: Management Factors


One turbine was stopped for minor repairs and adjustment. The generator’s excitation breaker and air-operated disconnect breakers were opened. When the turbine generator had nearly completed its…

A hydrogen leak occurred on the a coolant pipe of an electrical generator located in the turbine building, at 200 m from the reactor. Because of the welding works ongoing at that moment on the pipe,…

A leak of a compression fitting lead to the build up of an explosive air/hydrogen mixture in the generator pit. The ignition of the mixture was caused by corona discharge. The resultant explosion…

The explosion occurred in the condenser area of a steam turbine, two hours after the unit tripped due to a stator earth fault. The stator earth fault had damaged two hydrogen cooler tubes, which…

The incident started with the cracking of the low-pressure turbine blades. This caused an unbalance to turbine generator rotor which led to the failure of the bearings and the loss of confinement…

SYNOPTICs The loss of the hydrogen side sealing oil pump and other problems in the sealing oil system resulted in the coolant hydrogen leaking from the generator. The hydrogen leaked for several…
This incident occurred during maintenance works after an outage at a turbine and generator unit of the plant. At the time of the incident, 15 maintenance technicians had already been working on the…
A catastrophic failure of the low pressure turbine followed by fire and flooding severely damaged the generator. The main turbine automatically tripped due to an erroneous mechanical over speed…
A leakage and fire occurred during normal operation at a medium-pressure hydrocracker of a refinery. This unit perform a desulphurisation and a decomposition of heavy gas oil. High-temperature and…

This incident occurred at a unit designed to convert heavy oil residues into refined products. It involved a fluidized bed reactor and the related hydrogen supply system serving the optimisation…

The explosion occurred at the hydro-deoxygenation unit of a renewable fuels facility. Part of this unit is a furnace aiming at pre-heating renewable feedstock, recycled renewable diesel, and…

When waste alkali solution was taken out of dumper trucks into a waste liquid storage tank, a reaction occurred in the tank. As a result, the solution in the tank foamed over it, and reached an…
The incident occurred at the direct desulfurization unit of heavy oil. A 130×90 mm oval opening occurred in the bypass pipe of the hydrogen sulphide absorption tower for the circulating gas, at a…

This incident occurred at the storage system of a hydrogen refuelling station during an inspection. The inspection consisted in the visual inspection of individual pressure vessels of the storage…

At a nuclear power plant, a fire occurred in the station's hydrogen storage facility while the plant was operating at 100% power. The fire was reported to the control room by a non-licensed operator…
A fire at the exit of the vent line occurred when filling a tube trailer. An employee suspected a flame at the outlet of the hydrogen venting line during the filling of a trailer. , by sawing the air…
This incident occurred at CVD (coating vapour deposition) equipment. During operation, a vacuum pump for air discharging was turned on and by mistake silane and hydrogen gases were allowed to flow…

This incident occurred during the delivery of a hydrogen gas container to a customer site. When a worker turned the protective cap of the container, the valve handle turned together with the…

A compressed hydrogen tube trailer was fully loaded and parked in the sun. The heat caused a pressure build-up, so that a burst disc failed prematurely venting hydrogen, which ignited. 13,360 cu…

The incident occurred at the residual de-sulphurisation (RDS) unit of a refinery, during the initial start-up phase, consisting of the pressurisation by hydrogen of the unit reactors and the…