Fire from a CGH2 tube trailer just loaded
A compressed hydrogen tube trailer was fully loaded and parked in the sun. The heat caused a pressure build-up, so that a burst disc failed prematurely venting hydrogen, which ignited. 13,360 cu ft were released. [Zalosh and Short, 1978]
Event Date
November 5, 1975
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes

The INITIATING CAUSE was the premature failure of the burst dis. A CONTRIBUTING CAUSE was the increase of hydrogen pressure in the tubes of the trailer caused by heat flow from direct sun exposure The fact that the a common environmental condition such as sun exposure was enough to cause a disc to one, suggests CONTIBUTING or ROOT CAUSE possibly related to (i) not fully respecting operative instructions , or (ii) lack of attention to the over-heating aspects in the operative instructions (shortcoming in accidental scenarios setting and risk assessment).