Fire from a CGH2 cylinder
This incident occurred during the delivery of a hydrogen gas container to a customer site. When a worker turned the protective cap of the container, the valve handle turned together with the container, causing hydrogen gas to leak and ignite, resulting in the worker being burned.
Event Date
August 29, 1997
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences

The INITIATING CAUSE was the accidental (erroneous) opening of the release valve. The KHK report attributes the ROOT CAUSE to a wrong operation (bad handling). However, this incident should not be made possible by passive safeguards. The fact that it was possible reveal a mistake in the design of the equipment, which did not considered a possible wrong operation.