HIAD Causes: Management Factors


In a hydro-desulphurisation unit of a refinery, an operator which was performing a control tour heard noises and clicks on the hydrogen compressor and stopped it. The compressor was of a…

A hydrogen fire occurred at a hydrogen refuelling station (HRS). The HRS hydrogen storage consisted of two trailers at 200 bar, both connected via flexible hoses to the station delivery system…

The event occurred at a high-temperature heat of at a benzene manufacturing plant using a dealkylation reaction. High-pressure hydrogen leaked from a flange of the heat exchanger, during start-up…

The incident occurred at a refinery unit for the desulphurisation of a light heavy oil. This unit was equipped with three hydrogen compressors. Two of them were usually operated and the third was…
The broke out at a hydrogen compressor of the reforming unit of the refinery. Following the safety procedures, the emergency stop of the unit was activated and the unit was decompressed using a…
A fire developed on a mathanation reactor. The methanation reactor vessel was found to be deformed and had a 3-4 inch rupture at a position corresponding to the top of the catalyst bed. It is thougth…

A fire in a first stage 'pygas' (pyrolysis of gasoline) hydrogenation of a naphtha cracker was caused by escape of a mixture of gasoline, hydrogen and nickel catalyst through a crack in…

The boat was performing a drive test when one of the 280 lead gel batteries exploded and took fire. The local fire brigade was able to extinguish the fire but the above deck section of the boat was…
A major leak occurred at the outlet of the diesel hydrodesulphurisation furnace in a refinery. The furnace was just restarting. The released gaseous product ignited, and the alarms of the temperature…

A tube ruptured in the charge heater ('fired heater') of a desulphurisation reactor due to a blockage caused by accelerated coking. Flames spread over an area of some 100 feet outward…

While filling a 9 litre gas cylinder with pressurised hydrogen in the hydrogen storage area, a blast occurred which destroyed the low pressure gauge, followed by a jet fire which damaged the surface…
A man was burned when a fire broke out as a hydrogen cylinder was being changed in a governmental research centre. It was reported that the fire was started by a spark from a wrench. The sprinkler…

This incident occurred a product purge vessel flange during planned maintenance activities on a chemical plant. The vessel had the function to collect unreacted gases from a polyethylene…

In a plastics production plant, a pallet containing 7 cylinders of nitrogen and 1 cylinder of hydrogen fell from a truck traveling in a logistics zone. The driver stopped the vehicle, cut off the…

The incident occurred at the hydrocracker unit of a refinery. A mixture of hydrogen and hydrocarbon gas was accidentally released. The flammable gas formed a vapour cloud that ignited, resulting…

Three workers were asphyxiated when argon and hydrogen gas leaked from pipes they were installing on an aromatics plant being built on a cracking complex.
During a routine inspection, a flame was observed at the bottom flange of a reactor in a refinery. Few moments later, sensors near the leak detected a rise in temperature. The facility was shut down…
A diesel and gas leak (H2, H2S, CH4) occurred in a hydrodesulphurization unit (2,200 t/d). The leak location was on one of the boiler valves of the stabilization column. The released mixture (390 °C…
The leak ignited at the seal located between the bottom and the body of a heat exchanger of a desulphurization unit of a refinery. The fire is alimented by the leaking fuel under pressure for about…
Hydrogen ignition during welding on a VSC-24 spent fuel cask Pursuant to 10 CFR 72. 210 - fuel in an independent spent fuel storage installation at its Point Beach Nuclear Power Plant. The inspection…