Skip to main content

Fire on a naphtha cracker (666)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Fire on a naphtha cracker

A fire in a first stage 'pygas' (pyrolysis of gasoline) hydrogenation of a naphtha cracker was caused by escape of a mixture of gasoline, hydrogen and nickel catalyst through a crack in the wall of the reactor. Investigation showed that the crack was caused by a brief local temperature excursion, explained by a local disturbance and heat removal, attributed to a runaway reaction during the start-up (7 days previously) initiated by sudden increase in fresh feed added to the reactor. Excessive formation of carbon-like products impeded the liquid distribution.

Event Date
August 21, 1997
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments

Leak, runaway reaction and crack

Facility Information
Application Type
Application
hydrotreatment
Specific Application Supply Chain Stage
Components Involved

cracker and reactors and reaction equipment

Location Type
Operational Condition
Consequences
Number of Injured Persons
0
Number of Fatalities
0
Event Nature
Release Type
Release Substance
H2, naphta, nickel catalyst
Hydrogen Release Concentration (%)
0.00
Ignition Source
References
References

Event description extracted from the UK database ICHEME in PDF. The ICHEME database is no longer available for purchase, but data can be download as PDF for free. https://www. icheme. org/knowledge/safety-centre/resources/accident-data/(accessed October 2020)