Gas cylinders pellet fall in from truck in a plastics production plant (794)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Gas cylinders pellet fall in from truck in a plastics production plant

In a plastics production plant, a pallet containing 7 cylinders of nitrogen and 1 cylinder of hydrogen fell from a truck traveling in a logistics zone. The driver stopped the vehicle, cut off the engine and noticed a leak on the hydrogen cylinder; he warned his superintendent who alerted the firefighters, established a safety perimeter and interrupted any work with hot sources. The firefighters stopped the leak by closing the cylinder valve and put the basket back on the truck which was then unloaded at the place originally planned.
Event Date
December 16, 2013
Record Quality Indicator
Region / Country
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments
The INITIATING cause was the fall of the load from the truck. The analysis of he incident by the plant operator brought to these conclusions: -the gas delivery rate was unusual and the gas cylinder pallets suitable for trolley transport were not available; -the truck used as a replacement was not designed for the purpose and the load was not well secured; -the acceleration of the driver at start-up would have resulted in the fall of the basket. Therefore, the ROOT CAUSE was the decision to use inappropriate system to address increased frequency of the transport operations.
Facility Information
Application Type
Application
Plastic production
Specific Application Supply Chain Stage
Components Involved
Trolley, gas cylinders pallet
Storage/Process Medium
Location Type
Operational Condition
Consequences
Number of Injured Persons
0
Number of Fatalities
0
Lessons Learned
This is a typical case of lack of safety culture, revealed by the wrong decision under delivery time pressure.
Event Nature
Emergency Action
The driver stopped the vehicle, cut off the engine and noticed a leak on the hydrogen cylinder; he warned his superintendent who alerted the firefighters, established a safety perimeter and interrupted the work by hot spot. The leak stopped by closing the cylinder valve and replaced the basket on the truck which was then unloaded at the place originally planned.
Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
Detonation
No
Deflagration
No
High Pressure Explosion
No
High Voltage Explosion
No
References
References

ARIA data base event no. 45096