Fire on a methanation reactor
A fire developed on a mathanation reactor. The methanation reactor vessel was found to be deformed and had a 3-4 inch rupture at a position corresponding to the top of the catalyst bed. It is thougth that the incident was caused by ethylene entering the reactor. The ethylene reacted with hydrogen on the nickel catalyst, resulting in a very rapid release of energy. The corresponding temperature rise was sufficient to cause a ductile failure of the vessel. The proposed mechanism for the reaction is that ethylene vapour entered the methanation reactor via the cold box where there was a low pressure/high temperature following the trip. On re-pressuring, the ethylene was carried forward through the 90% hydrogen line to the reactor.
Event Date
August 23, 1990
Record Quality Indicator
Region / Country
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments
According to the ICHEME report (See References), the assumed INITIATING cause was a runaway reaction caused by the accidental injection of ethylene into the methanation reactor. The proposed mechanism for the accident is that ethylene vapour entered the methanation reactor via the cold box where there was a low pressure/high temperature following the trip. When re-pressuring, the ethylene was carried forward through the 90% hydrogen line to the methanation reactor.