The vehicle puling a compressed gas hydrogen trailer was on a highway transporting 420 kg of hydrogen. A car turn in front of it running a red light, so that the CGH2 trailer did not have time to…

This event occurred at the hydrogen 70 MPa dispenser of a refuelling station during the testing phase. Just after the start of the refuelling test, at a pressure of approximately 13 MPa, the…

This event occurred at a theatre building. A contractor was conducting routine maintenance on a dry pipe sprinkler system in the basement of the theatre. By opening the pipe, an explosion occurred…
An explosion occurred on a ship loaded with a cargo of 2333 tonnes of unprocessed incinerator bottom ash. Flammable gas generated by the ash produced two explosions: the first one was in the…

A vessel exploded at a plant producing pharmaceutical products. At the time of the incident, the plant was producing a substance called Dekon 139. The Dekon had already been synthesised, and…

The event occurred in a silicon hydride (SiH) emulsion production process inside an enclosed production building. The reaction was ongoing when one of the tank started overflowing with foam. The…
The soldiers of the Royal Prussian Air Ship Division stored large amounts of hydrogen gas. They kept some 1000 cylinders in a shed. On 25 May 1894 about 400 of them burst without apparent reason.…

An empty fuel cells and hydrogen bus out of service was returning to the refuelling station, when it collided with a low bridge. This resulted in the rooftop hydrogen tanks being sheared off. The…

The safety cabinet with compressed hydrogen was located in a laboratory and used to supply hydrogen to an experimental facility. The safety cabinet was equipped with exhaust extraction. Due to a leak…
This entry refer to a series of events occurred before the date given, which corresponds to the publication of the evidences at the Int. Conference on Hydrogen Safety 2015. The nozzle/receptacle…
The event occurred at one of the unit producing iron powder, consisting of a furnace with a running belt for the powder, kept under hydrogen atmosphere to reduce and purify the metal. The hydrogen…
The incident occurred in a hydrocracker unit of the refinery. A control valve on the liquid line between the high- and the low-pressure separators was erroneously opened and the liquid allowed to…
An explosion followed by a fire occurred at a tar precipitator of gas treatment of a coke oven. The extractors were manually activated. Ten minutes later, the operator activates the internal…
The explosion occurred in a benzene production unit (Litol process), which was being restarted following a scheduled shutdown for maintenance. About 30 kilograms of hydrogen gas were relesed into a…
SUMMARY The explosion occurred in a catalyst regenerator of the catalytic cracking unit in a fluidized bed during a technical shutdown. A few seconds later, a second explosion is perceived, it is the…

The incident occurred at a dispenser of a hydrogen refuelling station (HRS). The HRS employee had just terminated the filling of a fuel cell vehicle (FHV) and was depressurising the filling hose,…

The explosion occurred at a sand oil an explosion and affected the hydrogen compressor and its building, serving the hydrocracker unit. (1) More than two months before the incident, a large…

An explosion took place at a research facility of a university, due to an accidental release of hydrogen. Hydrogen gas was used in research reactors to deposit amorphous silicon thin films. The…
An explosion occurred inside a pipe of a boiling water nuclear power reactor. The pipe was part of a core spray system, which was providing extra cooling when shutting down the reactor. The system…
A release of "synthesis gas", containing primarily hydrogen occurred at the ammonia synthesis unt of a fertilisers plant. The location of the leak was a valve within the ammonia synthesis column. The…