A combustion event occurred in a liquid hydrogen tank (LH2) under a high pressure and in presence of 12 m³ (700 kg) of LH2, at a testing site for space equipment. A pressurisation test was being…
The explosion occurred when a spark from welding equipment ignited flammable vapours from a 415,000-gallon (ca. 1. 5 million of litres) sulphuric acid storage tank at the refinery. The investigation…
In a laboratory, tests with hydrogen as aerospace rocket propellants were carried out. One of the experiments consisted in the generation of a vertical jet (turbulent regime) to determine the sound…
In a chemical plant (SEVESO), corrosion on the water side of a cooling exchanger caused water to enter the sulphuric acid and attack the steel in the tank. This reaction produced hydrogen that…
A hydrogen fire occurred in a nuclear power plant outside the controlled area. The leaking point was on a pipe system of the distribution circuit of the gas network (6 bar nominal working pressure).…
The incident occurred outside a fuel cells manufacturing facility. While preparing for transfer of liquid hydrogen from tanker truck to a stationary storage tank, a release of hydrogen occurred,…

The incident occurred at a hydrogenation reactor producing alcohols. At the time of the fault, the plant was in normal operation. A sudden leak of hydrogen occurred on the flange of the upper…

On February 3, 1994, a control room operator at Surry Power Station, Unit 1, observed pressure spikes on the pressurizer level instruments. At the same time, a loud rumbling sound was heard in the…
[NOTE of HIAD Validator: the attribution to hydrogen formation as cause of the explosion is 'probable 'but not fully demonstrated]. Two explosions in two different sprinkler systems occurred, wit the…

The event occurred during the fuelling process of the primary fuel tank of the core stage of a moon rocket. The initial slow-filling phase was terminated, and personnel had just started the fast…

The leak occurred at an heat exchanger of the hydro-isomerisation unit of a refinery. Following the observation of a pressure drop between two heat exchangers, controls were carried out on site. A…

This incident occurred at a 70MPa hydrogen refuelling station. After completing a filling test, the pressure in the filling hose suddenly dropped. A worker heard the hissing sound of a hydrogen…

The event occurred in a bus garage when carrying out the purging process of the hydrogen cylinders. This process was executed via an electronic control system, but it was found that one cylinder…
A fire broke out on the world’s first hydrogen carrier vessel shortly before setting sail from Australia to Japan carrying the world’s first international shipment of liquefied hydrogen. A flame was…
A 50-litre standard hydrogen gas cylinder was temporarily placed and used in a laboratory. The hydrogen gas was used for a flame ionization detector (FID) in gas chromatography (GC) instrument. The…
The accident occurred at a production, distribution and storage station for hydrogen city busses. After filling the hydrogen cylinders of a bus, the hydrogen detection system of the bus triggered an…
The incident involves a gas booster provided by a manufacturer. This device is used in the experimental platform of the project to raise the pressure in pipelines from 60 to 80 barg (from 6 to 8 MPa)…

A leak developed on a main connector to a pallet consisting of 12 hydrogen bottles, which had not been re-tightened for a few weeks. The alarm, at at 5% of the LEL, went off , with automatic call…

A hydrogen leak occurred during refuelling of a fuel cell-powered lift truck. The forklift was depowered. This was the first refuelling after the replacement of the in-tank shutoff solenoid valve…

The incident occurred when refuelling with hydrogen a fuel cell forklift. The hydrogen was provided by a mobile refuelling station. The filling of a second forklift of the day had just begun, when…