Skip to main content

HIAD Quality Indicator: 5


A leak occurred at an underground steel pipeline (6 inch) transporting pressurised hydrogen (75 bar). The leakage lasted for at least several hours, but it cannot be excluded that the leakage started…
A hydrogen fuel tank release caused a fire at a hydrogen refuelling station. A pressure relief valve installed on one of the 18 storage tanks failed at a pressure far below its design opening value.…
The accident originated in the isomerisation unit and propagated to the benzene saturation unit. The accident source was a mechanical rupture of one of the two compressors used to transfer hydrogen…
A 24" pipe carrying synthesis gas (Hydrogen = 43. 5%, Nitrogen = 14. 08%, Methane = 0. 2%, Carbon Dioxide = 12. 3%, Water = 29. 3% by volume) ruptured. About 60 kg of hydrogen contained in the gas…
As the airship approached the docking mast, it performed a sharp turn to face into the wind, which was shifting. The engines were run at full speed astern for about a minute to slow the airship. Dust…
A release of compressed hydrogen and subsequent fire occurred during the transportation of a CGH2 trailer by means of a truck tractor. The tube trailer module contained 25 fully wrapped carbon filler…

30 pounds of gaseous hydrogen (14 kg) were accidentally released from a heat exchanger at a refinery. The location was the flange between the heat exchanger channel and shell and occurred during…

A fire developed on a tube trailer transporting 330 kg of compressed hydrogen, while travelling on a highway. The truck had left a plant of hydrogen production and storage to deliver to a refuelling…

This incident happened during a test of a hydrogen engine prototype vehicle, equipped with on-board liquefied hydrogen storage. The hydrogen gas leaked from a hose joint of a flexible pipe in the…

While filling a 9 litre gas cylinder with pressurised hydrogen in the hydrogen storage area, a blast occurred which destroyed the low pressure gauge, followed by a jet fire which damaged the surface…
A fire broke out affecting the heavy fuel purification plant of the refinery. The incident could have originated by the failure of one of the following plant components: - pipes leading to the…

The incident occurred at the hydrocracker unit of a refinery. A mixture of hydrogen and hydrocarbon gas was accidentally released. The flammable gas formed a vapour cloud that ignited, resulting…

During a routine inspection, a flame was observed at the bottom flange of a reactor in a refinery. Few moments later, sensors near the leak detected a rise in temperature. The facility was shut down…
Hydrogen ignition during welding on a VSC-24 spent fuel cask Pursuant to 10 CFR 72. 210 - fuel in an independent spent fuel storage installation at its Point Beach Nuclear Power Plant. The inspection…

Hydrogen was accidentally released into the compressor room of a hydrogen refuelling station. The fixed gas detector in the compressor room issued a value of 48% vol. of he Low FLammability Level,…

A Worner 1000 STU gas balloon, of German registry D-OAGH, piloted by a commercial pilot was substantially damaged during landing, when the hydrogen-filled envelope came in contact with a power line,…
The event occurred in a support building at a test stand complex. The explosion destroyed two support buildings and severely damaged a large amount of equipment. No one was injured. Gaseous hydrogen…
The hydrogen buffer tanks that exploded were part of an experimental facility experimenting generation of renewable hydrogen from a water electrolyser coupled to solar panels. The three hydrogen…
An open backed truck was delivering various to various sites industrial gases, among which hydrogen. At the site of the explosion a rack of argon gas bottles was being delivered to a laboratory in…
The event occurred at manhole cover of a of a pilot plant reactor where hydrogenation had been performed in a hydrochloric aqueous solution. The reactor had been flushed three times with nitrogen (i.…