Skip to main content

Fire on a hydrogen vehicle (976)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Fire on a hydrogen vehicle

This incident happened during a test of a hydrogen engine prototype vehicle, equipped with on-board liquefied hydrogen storage. The hydrogen gas leaked from a hose joint of a flexible pipe in the engine compartment. The leaked hydrogen ignited and a fire developed, involving also brake oil. The engine test, which consisted in a real run of the vehicle, had started 6 hours before the incident. The driver left the vehicle when he saw smoke coming out of the engine compartment. Nobody was injured. The fires was extinguished with water and dry chemicals extinguishers.

Event Date
March 8, 2023
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments

INITIATING CAUSE: the fastening part of the flexible pipe connected to the engine loosened due to engine vibration, causing hydrogen gas to leak . IGNITION CAUSE: The leaked hydrogen ignited because it came in contact with high-temperature objects, such as the exhaust manifold and turbocharger of the 700 and 900 engines. Nearby flammable materials (brake oil) also burned, causing smoke. ROOT CAUSE: they could be related to error during installation (incorrect fixing of the hose) and/or to a design problem (underestimating the intensity of vibrations).

Facility Information
Application Type
Application
ICE-hydrogen vehicle
Specific Application Supply Chain Stage
Components Involved

hose, pipe, engine

Storage/Process Medium
Actual Pressure
1
Design Pressure
1
Location Type
Location description

DESCRIPTION OF THE VEHICLE The vehicle was had an internal combustion engine, fed by an on-board liquefied hydrogen fuel storage. The vehicle fuel supply system pressurised the liquefied hydrogen by means of a pump and vaporized it in an evaporator. The hydrogen gas was then directly injected into the engine via a pressure chamber. The pressure chamber is designed to store a fixed amount of hydrogen gas in order to accommodate fluctuations in fuel consumption.

Operational Condition
Pre-event Summary

6 hours before the incident occurred, a test run had started.

Consequences
Number of Injured Persons
0
Number of Fatalities
0
Environmental Damage
0
Property Loss (onsite)

0

Property Loss (offsite)

0

Post-event Summary

No injury. No damage.

Lessons Learned

Dismountable joints and connections represent components which are particular prone to leak hydrogen. When they are unavoidable part of a hydrogen supply systems, specific design measures have to be taken to minimise leakages and to mitigate the effect of them. Therefore: (i) The piping should be designed to facilitate the tightness of joints. (ii) Hot surface should be avoided in the surrounding of joints. (iii) Vehicles vibrations should be characterised and appropriate measures must be taken to prevent fatigue damage of piping and loosening of fastening parts. When using flexible tubes for piping, it is more effective to use bellows tubes, which have better vibration resistance than spiral tubes. Regarding measures to prevent loosening of fastening parts, the selection and fastening management of joints around compressors in liquefied petroleum gas vehicles, natural gas vehicles, fuel cell vehicles, and stations that supply each fuel can be used as a reference.

Event Nature
Emergency Action

9:00 The engine test starts 15:00 The control system detected a hydrogen leak and issued a display and alarm. • The liquefied hydrogen fuel vehicle's control system stopped automatically the fuel supply and shut down the engine. • The driver of the liquefied hydrogen fuel vehicle saw smoke coming from the engine compartment, so he stopped the vehicle and left it. • The course rescue and racing team workers began extinguishing the fire using a carbon dioxide fire extinguisher. • The course rescue and racing team workers used up all the extinguishing agent in the carbon dioxide fire extinguisher, but were unable to put out the fire, so they switched to water and dry chemicals to put out the fire. • The course rescue and racing team workers confirmed with a hydrogen detector that the hydrogen leak had stopped and visually confirmed that the fire had been extinguished.

Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
References
References

KHK accidentl database, incident 13_2023-100: https://www. khk. or. jp/public_information/incident_investigation/hpg_incident/gen_lp. html (accessed august 2024)

KHK accidentl database, incident 13_2023-100. pdf: Enghlish version of the Japanese original, based on Google machine translation