Fire on a hydrogen tube trailer
A fire developed on a tube trailer transporting 330 kg of compressed hydrogen, while travelling on a highway. The truck had left a plant of hydrogen production and storage to deliver to a refuelling station. The probable origin of the incident was a fire on the rear tyres of the trailer, which caused the overheating of the tubes, increasing the internal pressure and the consequent opening of the pressure relief valve. The investigation determined that the released hydrogen ignited twice, forming a jet flame. This suggests that only two of the tubes had the pressure relief valve activated. In the video, only one flame is visible. The flames reached 10 to 20 m. The fire brigades were able to extinguish the file in 30 minutes.
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments
The INITIATING CAUSE was a conventional fire which triggered the activation of the safety device of two of the hydrogen tubes when their internal pressure rose due to the increased temperature. The ROOT CAUSE is of difficult attribution. Nevertheless, considering that such a scenario must be prevented, the design of the trailer-tractor system would need improvement and the inspection and requalification procedures for trucks carrying hazardous materials made stricter.