An isolation failure in starter coil of the high voltage generator induced an electric arc to the hydrogen supply line, with consequent fire and melting of the line. [Zalosh and Short, 1978]
A tube in a hydrorefiner heater ruptured resulting in an extensive fire inside and outside the furnace. The main fire in the furnace was extinguished within 15 minutes and the escaping gas / vapour…
A leak occurred on a 4 inch hydrogen main gas line which ran along a pipe bridge at the east end of a first stage compression plant building. The relased hydrogen ignited. The source of ignition was…
Employees were refilling a rack of 15 hydrogen cylinders that were connected together on a steel pallet with railings. A leak developed at a valve and the pressurized hydrogen ignited. Operations…
The incident took place on the reforming furnace unit of the plant. Around 23:30 pm, during a normal inspection tour, an operator detected a fire on a section of a steam line. The operator…
Fire on a filter of an autoclave. The event occurred in a plant for the production of plastics. After catalytic synthesis of amines, the filter of the autoclave was taken out for cleaning. During the…
A rupture of a tube in the furnace of an oil refinery caused it to loose 700 pounds of diesel and hydrogen resulting in a fire. The fire burned for a half hour with 30- to 40-foot (10 to 12 m) flames…
The event occurred at the in the distillate hydrotreater unit of a refinery. This unit was using hydrogen to remove sulphur from a hydrocarbon feedstock. A 12-inch overhead pipe ruptured with a loud…
A fire on a pipe providing hydrogen to a a refinery, causing a light injury to a worker. Company and local fire departments intervened. The were able to extinguish the fire in 2. 30 h.
A fire started as a result of an explosion in the process section of a refinery. An open structure of steelwork protected with reinforced concrete housed the usual furnaces, reactors, heat exchangers…
The fire, 1 m high fire occurred in a pipe at the inlet of the hydrodesulphurisation unit of a refinery. The fire was caused by the leak of the pipe content, hydrogen and diesel fuel. According to…
The event occurred in an alkylation reactor. Due to the rupture of a pipe (probably due to material failure), a power failure took place and the plant was automatically put in hot-stand-by mode. This…
A short circuit occurred in a bus bar system in a transformer building, causing a fire in adjacent switches. This was followed by the tripping out of the three refinery turbo-alternators, cutting off…
Due to the failure of a exhaust system, compressed hydrogen leaked into an area containing electrical components, with consequent fire. Leakage was allowed when exhaust system failed.
The accident occurred on the hopper fine powders from a pair of cyclones (the hopper is the bottom conical part of the cyclone collecting the powder/dust separated from gas phase). A bursting disc…
The fire was in a polyamide production chemical plant classified SEVESO During maintenance of an isolated unit producing a polyamide monomer (LACTAME), a fire developed on the ground floor of the…
A fire broke out at a flange inside a heat exchanger of the catalytic reforming unit of a refinery. This heat exchanger had the purpose to pre-heat the load of heavy oil and hydrogen by recovering…
A fire occurred at the desulphurisation unit of a refinery during maintenance work. On the day of the incident, a distillation unit was shutdown for a steam air tightness test. A leak was found at…
The accident occurred in the de-sulphurisation unit, and specifically on a pipeline at 50 bar, for the recycling of the hydrogen (containing hydrogen sulphide impurities). The pipe failed due to…
The event occurred at the charge heater of a hydrodesulphurisation reactor. The vertical cylindrical fired heater was used on the charge to a hydrodesulphurisation reactor. The flow was two-phase at…