The event occurred at the charge heater (also called a 'fired heater') of a vertical cylindrical hydrodesulphurisation reactor. The heater lost hydrogen flow briefly while the unit was being changed…
A hydrogen skid was placed into service in a nuclear power plant, outside the controlled area. This skid, like seven others, was located in a gas cylinder storage facility. It was supplied by several…
An explosion occurred inside the hydrogen washing tower of a chlorine production plant. The explosion was preceded by an abrupt reduction in the electrolysis flow due to a rectifier malfunction. The…
A fire started on the primary hydrogenation reactor of a chemical plant synthesizing alcohols and acids by reactions between olefins and a H2 / CO gas mixtures. The alcohols are synthesised in 3…

During preparation of a spacecraft LH2 tank in an environmental test chamber, a liquid hydrogen fire occurred in the chamber. The tank was being "topped off" at the time. Damage was…

The event occurred on vent stack of an ammonia synthesis unit. The release of the gas was more specifically on the water purge line or the hydraulic guard of the vent stack. The process gas…
The fire occurred on the tube plate gaskets of 3 of the 4 exchangers loaded with catalytic reforming effluent. The fuel (500°C and p=30 bar) was a mixture of 30% hydrocarbons and 70% hydrogen. After…
Release of gas from a coking plant on a gas holder which ignited causing a fire. The accident took place during repair works. The gas was made of 65 % of hydrogen , 25 % of methane , 4. 1 % of carbon…
A fire developed at a recycle gas compressor of a refinery. During recommissioning, the compressor, belonging to a hydro-treatement unit, was overpressurised. The cylinder head was blown off,…

In a hydro-desulphurisation unit of a refinery, an operator which was performing a control tour heard noises and clicks on the hydrogen compressor and stopped it. The compressor was of a…

Gaseous hydrogen release in generator caused by turbine vibrations [Zalosh and Short, 1978]

The incident occurred in the hydrogen sulphide absorption tower of the kerosene desulphurisation unit of a refinery. The hydrogen leaked from the liquid level gauge and ignited causing a fire. The…

The incident occurred at a university facility, in the premises of a spin-off company. A worker was checking the hydrogen pressure by opening the main valve on a hydrogen cylinder, when hydrogen…

The fire developed an early morning on a hydrogen bus at a refuelling station for public transport. According to the bus company release, one bus was destroyed by fire suring refilling and the…

A fire started in the night on one of the fuel cells and hydrogen bus of a garage of a public transport company. There were seven buses parked on a parking lot outside. 6 buses were destroyed by…

The broke out at a hydrogen compressor of the reforming unit of the refinery. Following the safety procedures, the emergency stop of the unit was activated and the unit was decompressed using a…

This incident occurred at a refinery, on a pipe transporting hydrogen at 24 bar placed at 6 m above ground. A 15 cm long hydrogen flame was detected at an anti-leak system temporarily installed on…

The incident occurred when delivering liquid hydrogen to a stationary storage system of a semiconductor plant. Cold gaseous hydrogen was vented for unknown reason, ignited and created a plume of…
A weld on a 1 inch diameter instrument tapping from a Octafiner reactor overhead line fractured, resulting in a small but intense fire, lasting about 50 minutes until the unit was nitrogen purged.…

This event occurred when dismantling the cryostat. While a hot air dryer was being used to free a coupling in a hydrogen cryostat, a flash fire occurred. [Ordin, NASA (1974)]