A leak developed on a CGH2 tube trailer on the pigtail of one of the tube. The pigtail was cracked, possibly due to vibration. This trailer was tested the day before this incident and was found to…
A liquid hydrogen tanker had completed the off-loading at a customer’ site (metal manufacturer). The drivers were preparing to disconnect from the customer’ tank, when they noticed a small leak at…
The driver of a liquid hydrogen tanker noticed a small plume at the rear while traveling on a highway. He pulled over and found that the manual vent valve had opened due to vibration. The valve…
A LH2 trailer/truck were travelling on a highway when they noticed vapour coming from the trailer cabinet. They exited the highway, parked and opened the trailer cabinet. They found that a nut had…
A liquid hydrogen tanker was parked at a parking place. The vacuum on the tanker vessel deteriorated causing inner container pressure increase. When the inner container pressure reached the…
While travelling on a highway, the driver of a liquid hydrogen tanker noticed vapour coming from under the tank control cabinet. The driver stopped at rest stop and notified the home terminal,…
A liquid hydrogen tanker was travelling to a customer when the driver noticed that hydrogen release was occurring at the trailer vent stack. The driver stopped the vehicle in a safe location and…
A liquid hydrogen tanker was travelling on a higway, when the vacuum guranteeing the thermal insulation of the tank started to degrade. The increased heat transfer caused a pressure build-up and…
The driver of a liquid hydrogen tanker noticed a small plume at the rear of the track. He pulled off at the next exit and found that the manual vent valve was open due to road vibration. The valve…
A tanker was returning to the base after delivery of liquid hydrogen at a space centre. The driver tanker noticed a small plume at the rear of the track. He pulled off at the next exit and found…
A liquid hydrogen tanker was driving on a highway, when the driver noticed a vapour plume in his mirror. Driver stopped and found a small amount of vapour coming from the vapour recovery line,…
A LH2 trailer was delivering liquid hydrogen to a customer. Once finished the delivery, the driver noticed a leak on the piping between the trailer and vent valve inside the side cabinet. The…
The incident occurred at the ammonia synthesis unit of a production plant of fertilizers (Seveso III upper tier), during the operation of start-up. The unit was restarting, when a pipe carrying…
An unscheduled venting of a stage LH2 tank occurred, creating a hazardous condition for personnel and creating a potential explosion/ fire. [Ordin, NASA (1974)]
During loading of a LH2 storage tank, the vent valve on the tank was opened and then ignition occurred near the instant that the valve was fully open. A light pressure wave was produced. The cloud…
A private car crashed against a hydrogen storage system at the gate of a company processing metals (Seveso plant). The storage consisted in two bundles made of several bottles each, containing…
During transfer operations of a liquid hydrogen from a tanker, a release of hydrogen occurred, which resulted in the detection of hydrogen in an adjacent building. The normal procedure could not…