A leak developed on a CGH2 tube trailer on the pigtail of one of the tube. The pigtail was cracked, possibly due to vibration. This trailer was tested the day before this incident and was found to…

A liquid hydrogen tanker had completed the off-loading at a customer’ site (metal manufacturer). The drivers were preparing to disconnect from the customer’ tank, when they noticed a small leak at…

The driver of a liquid hydrogen tanker noticed a small plume at the rear while traveling on a highway. He pulled over and found that the manual vent valve had opened due to vibration. The valve…

A LH2 trailer/truck were travelling on a highway when they noticed vapour coming from the trailer cabinet. They exited the highway, parked and opened the trailer cabinet. They found that a nut had…

A liquid hydrogen tanker was parked at a parking place. The vacuum on the tanker vessel deteriorated causing inner container pressure increase. When the inner container pressure reached the…

While travelling on a highway, the driver of a liquid hydrogen tanker noticed vapour coming from under the tank control cabinet. The driver stopped at rest stop and notified the home terminal,…

A liquid hydrogen tanker was travelling to a customer when the driver noticed that hydrogen release was occurring at the trailer vent stack. The driver stopped the vehicle in a safe location and…

A liquid hydrogen tanker was travelling on a higway, when the vacuum guranteeing the thermal insulation of the tank started to degrade. The increased heat transfer caused a pressure build-up and…

The driver of a liquid hydrogen tanker noticed a small plume at the rear of the track. He pulled off at the next exit and found that the manual vent valve was open due to road vibration. The valve…

A tanker was returning to the base after delivery of liquid hydrogen at a space centre. The driver tanker noticed a small plume at the rear of the track. He pulled off at the next exit and found…

A liquid hydrogen tanker was driving on a highway, when the driver noticed a vapour plume in his mirror. Driver stopped and found a small amount of vapour coming from the vapour recovery line,…

A LH2 trailer was delivering liquid hydrogen to a customer. Once finished the delivery, the driver noticed a leak on the piping between the trailer and vent valve inside the side cabinet. The…

The incident occurred at the steam methane reformer unit producing hydrogen. The event occurred just after that start-up steam was introduced into the reformer furnace inlet. At this moment a very…
A dye beam operator was drawing concentrated sulphuric acid into a plastic pail. He added to this pail the contents of a "drip pail" which had been located under the 55 gallon acid drum. The pail…
An empty 100-m³ reservoir of sulphuric acid (H2SO4) exploded at 9:15 am at a chemical site. Installed directly above its retention basin at a height of several metres, this reservoir was projected…
To repair a corroded flange on a 4500 litre sulphuric acid bowser outlet pipe, an angle grinder was being used to prepare the surface for welding. Within a few seconds of starting work there was a…
A university lab was investigating the production of hydrogen and methane from biomass made of wooden chips or sawdust. The experimental furnace was a concrete cylindrical furnace of the diameter of…
There was a small leak of syngas (a mixture mainly consisting of hydrogen and carbon monoxide) resulting in a localised fire at a bolted flange joint on the outlet carbon steel pipework of the High…
The leak occurred at the ammonia reactor after a technical shutdown of 4 days. When the production was resumed and the syngas compressor restarted 14 hours later, a jet-fire occurred. The Internal…

The incident occurred at the ammonia synthesis unit of a production plant of fertilizers (Seveso III upper tier), during the operation of start-up. The unit was restarting, when a pipe carrying…

Following a trip caused by the safeguarding of an ammonia production line, the syngas released into the atmosphere and ignited.
The event occurred while re-starting the ammonia production unit after a technical stop, a synthesis gas (50% hydrogen, 17% ammonia, methane and nitrogen) leak ignited on a flange located just after…
The release of a blast furnace gas occurred at a section of pipework, due to the rupture of valve seal. The gas did not ignite and the fire service attended as a precaution. The gas was both…
Two workers were performing maintenance or repair work on a brine surge tank, which potentially contained hydrogen gas in a vapour space in its upper portion. The job consisted in removing and…
In the collective treatment plant of a chemical platform, the truck tank of 25 m³ containing hydrochloric acid (HCl) rose in pressure at 11 am; leakage of acid solution and gas evolution occurred in…
Fire of drums containing lithium metal powder: Spontaneous combustion took place at drums containing lithium metal powder which were charged with argon gas for experiments. While lithium metal powder…

An unscheduled venting of a stage LH2 tank occurred, creating a hazardous condition for personnel and creating a potential explosion/ fire. [Ordin, NASA (1974)]

During loading of a LH2 storage tank, the vent valve on the tank was opened and then ignition occurred near the instant that the valve was fully open. A light pressure wave was produced. The cloud…

A private car crashed against a hydrogen storage system at the gate of a company processing metals (Seveso plant). The storage consisted in two bundles made of several bottles each, containing…

During transfer operations of a liquid hydrogen from a tanker, a release of hydrogen occurred, which resulted in the detection of hydrogen in an adjacent building. The normal procedure could not…