Small release from a LH2 tanker
While travelling on a highway, the driver of a liquid hydrogen tanker noticed vapour coming from under the tank control cabinet. The driver stopped at rest stop and notified the home terminal, which dispatched mechanics to the scene. They found that the pipe the relief valve was cracked. The tank was switched to alternate pressure safety system and transported for approximately 30 miles to the home terminal without further incident. The piping was repaired and all other trailers belonging to the same series were inspected for similar problem.
Event Date
July 20, 1995
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences

The INITIAL CAUSE wasthe failure of the pipe connectiong the tank to the pressure relief valve. Sincethe failure was attributed to road vibration, the ROOT CAUSE is related to shortcoming in design.