Small release from a LH2 tanker due to road vibration
A liquid hydrogen tanker was travelling on a higway, when the vacuum guranteeing the thermal insulation of the tank started to degrade. The increased heat transfer caused a pressure build-up and the rupture of the burst disc. (R. G. Zalosh and T. P. Short, COMPARATIVE ANALYSIS OF HYDROGEN FIRE AND EXPLOSION INCIDENTS, Quarterly Report No. 2 for Period December 1, 1977 - February 28, 1978, COO-4442-2, Factory Mutual Research Corporation, Factory Mutual System, Morwood, Massachusetts 02062)
Event Date
August 2, 1971
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Causes

The INITIATING CAUSE was the deterioration of the thermal insulation of the cryogenic tank The ROOT CAUSE unknown.