Compressed hydrogen was released from a storage system due to the rupture of a Bourdon-type pressure gauge. [Zalosh and Short, 1978]
A hydrogen leak took place on a trailer carrying compressed hydrogen, located inside the fenced perimeter of a hydrogen station. According to the company managing the hydrogen delivery and refuelling…
A liquid hydrogen tanker was travelling on a highway, when the driver noticed vapour exiting the rear tanker cabinet. The driver stopped the vehicle in a safe location and discovered that the vapour…
A truck carrying 6,000 gallons of liquid hydrogen (1,600 kg) experienced an accidental loss of confinement while travelling. The truck driver noticed a white vapour cloud coming from the rear of his…
The incident happened during a liquid hydrogen delivery at a customer site. When the drivers were pressuring up the tanker for product transfer, the safety relief system rupture disc failed…
A faulty rupture disc failed prematurely releasing 750 cu ft of hydrogen (0. 2 kg). [Zalosh and Short, 1978]
The vacuum on a liquid hydrogen tanker was lost, resulting in a hydrogen release, both manually and through bursting of burst disc [Zalosh and Short, 1978]
A faulty burst disc on a liquid hydrogen tanker failed prematurely releasing 750 cu. ft. of of hydrogen. [Zalosh and Short, 1978]
Due to a loss of confinement of the inner shell of the liquid hydrogen tank, the vacuum of the external shell was destroyed. The reduced thermal insulation capacity of the shell caused evaporation…
The vent valve on a liquid hydrogen tanker vibrated open allowing a slight discharge hydrogen. [Zalosh and Short, 1978]
An unexplained loss of vacuum resulted in the release of all the transported hydrogen by manual venting and and opening of the relief valve. [Zalosh and Short, 1978]
A LH2 trailer was preparing to unload, when the pressure in the tank rose to about 165 psi (11. 3 bar) and caused the burst disc to rupture. The whole tank content was vented to atmosphere.
The rupture disc installed on a liquid hydrogen tank failed, in a plant producing organic chemicals, during the weekly shut down. The hydrogen ignited at the exit of the exhaust chimney. The fire and…
A liquid hydrogen leak occurs in a steel plant on a 42000 l tank of liquid hydrogen. A sealing coupling was installed to stop the leak.
Furnace tube leak caused excessive heat on H2 tube causing rupture [Zalosh and Short, 1978]
A hydrogen feed line ruptured without igniting at an oil refinery.
A release occurred from a high-pressure hydrogen storage vessel at a hydrogen refuelling stations. Immediately after detection, hydrogen was vented out as a safety measure. There was no injury,…
The released occurred at a T-coupling small of a small pipe (possibly around 6 mm in diameter) in a gas storage system consisting of 40 vertical steel cylinders of 50 l each in a container. At the…
A hydrogen leak occurred on a flange located on a pipe coming from the hydrogen storage tank. The staff was confined and the Internal Operation Plan was launched. Helium was injected in the tank and…
A small release of hydrogen occurred after the collision between a truck containing liquid hydrogen and a truck containing manganese dioxide on a highway. Due to the release, the traffic was…
The release occurred at a composite pressure vessel on the roof of a refuelling station (in the form of a ISO-container). The leak occurred on a treated connection to the vessel. The vessel…
A leak occurred on the safety valve of a train wagon transporting liquid hydrogen. The train was composed of 10 wagons. The train was stopped on the railway several hours to allow depressurisation of…
A pipe of a hydrogen storage system (240 m³) breaks. The staff is evacuated and a perimeter of protection is put in place.
a hydrogen recycle compressor shut down unexpectedly, resulting in flaring activity with visible smoke.
A leak occurred on a rack containing 12 cylinders of hydrogen (50 l at 200 bar each) delivered by a lorry inside the fenced storage area of a bulb manufacturing plant. The plant’s safety manager…
A road tanker was being loaded with liquid hydrogen from a 15,000 gallon storage tank, when fire broke out after 1 inch rupture disc failed, ignition source was a loose connection in down stream…
The vent occurred at a hydrogen refuelling station (HRS) of a research laboratory (not public) serving heavy- and light-duty vehicle. The affected dispenser was a 700-bar dispenser for light-duty use…
The accidental hydrogen release occurred when testing the storage system connected to a PEM electrolyser. The leak test consisted in filling the storage with hydrogen at step-wise increase of…
A joint failure allowed a mixture of hydrogen and nitrogen into the atmosphere. Failure of double cone joint on waste heat boiler in synthesis loop caused release of synthesis gas at 28. 7 MPa and…
The incident occurred in a plant producing organic chemistry products. Hydrogen leaked briefly from an hydraulic valve. There has been no victim.