An in-line inspection of the hydrogen pipeline was being conducted and prior to the last run of the in-line inspection tool (magnetic flux leakage), hydrogen gas was released and ignited from a blind…
A tractor - semitrailer with horizontally mounted cylinders filled with compressed hydrogen struck a northbound pickup truck that had veered in front of it. The tractor-semitrailer then lost control…
During a gaseous hydrogen trailer filling operation, a burst disc relieved, causing a gas release. The gas flow caused the vent pipe to separate at the flared tube fitting, resulting in a fire.…
[Note of HIAD event validator: the description of this incident presents aspects which hinder the full understanding of the event sequence: for example, the PHMSA report uses the term ‘purge’ to…
While de-plugging a cooling circuit, a blockage suddenly released, causing a heavy movement of a flexible hose connected to the system. The flexible hose hit several small pipes and one employee…
Minor leak in the break-away coupling for 35MPa dispenser of a refuelling station for buses. The leak developed in the break-away coupling during a controlled test refuel. The test was attended by…
The event affected the hydrocracker unit. A sudden release into a cracker compressor flare header destroyed a safety relief valve and damaged a sight glass on a liquid collection pot. As a…
A CGH2 tube trailer was parked at a gas shipping site and was transferring gaseous hydrogen to a stationary storage system. The transfer hose failed releasing hydrogen, which ignited. The…
During transfer from a tank trailer to a stationary storage tank, a leak developed resulting in an unignited release. [Zalosh and Short, 1978]
Hydrogen leak occurred during a delivery of hydrogen at an automotive supplier. Rescue deployed a curtain of water and evacuated 82 employees from several companies within a radius of 50 m. The…
A leak occurred in a vehicle carrying 218 cylinders of hydrogen. The contents of 28 cylinders, 90 m³ of hydrogen, escaped. A security perimeter was set up with stop of the road and rail traffic.
A leak occurs at a flange on a hydrogen gas transport. The load consisted of 9 cylinders of 80 m³ each. The producer of these cylinders decides to let it leak. No consequences to report.
A LH2 road transporter experienced a fire on a rear tire. The driver tried unsuccessfully to extinguish the fire out with the on-board fire extinguisher, then he called the 911 and disconnected the…
Approximately 250kg hydrogen gas released from vent stack following failure of a relief valve on bulk hydrogen installation. No ignition and no injuries. The system had been recently installed. It…
A burst disc opened prematurely at a research facility, during a hydrogen tube trailer filling operation. The disc failed at 87% (5200 psig, approximately 36 MPa) of the final pressure (6000 psig,…
A truck loaded with hydrogen gas cylinders bundles (3 bundles of 30 cylinders, 1 bundle of 12 cylinders) was traveling on a seaside road. The nylon rope holding the bundles broke due to excessive…
A pressure relief device (frangible burst disc) on one of a 26 tubes on a tube trailers failed prematurely and released hydrogen while filling a hydrogen storage tank at a government facility. The…
A leak of 700 l of gaseous hydrogen was detected around on a connection of a rack of cylinders on a trailer truck, in aircraft plant (classified Seveso, lower tier).
A CGH2 tube trailer had been filled at the production facility and was parked awaiting pickup by the company. A rupture disc failed on one of the cylinders resulting in the release to the atmosphere…
A release of hydrogen occurred on a trailer during filling a stationary hydrogen storage tank. A pressure relief device (burst disk) on one of the tube failed prematurely and released hydrogen.…
A leak occurred on a line connecting the hot separator to the cold separator of a refinery diesel desulphurization. The alert was given by the activation of the fixed H2S detector. The 30 bar…
A hydrogen and fuel cells bus experienced a hydrogen detection alarm in a city centre. This triggered the evacuation of the immediate surroundings and the towing of the vehicle to the maintenance…
A hydrogen leak occurred on a makeup gas line of a gas oil hydrotreater unit of a refinery. The release location was a 1-inch gate valve, which later was found 10% open and with no bull plug. The…
A truck-trailer carrying compressed hydrogen cylinders stopped on an highway and reported a hydrogen leaking from the cylinders. The highway was immediately closed in both directions. When the fire…
A sudden failure occured on a hydrogen line of a refinery desulphurisation unit. The equipment was located between a hydrogen compressor and its overpressure protection valve. It was equipped with an…
During maintenance work on a gas pipeline carrying hydrogen , a worker hears a leak at about at a bridge. The operator measures an concentration of 3% of the low flammability limit at few centimetres…
This incident occurred on a hydrogen production device during the Great Hanshin Earthquake (Hyogo Prefecture Southern Earthquake). Hydrogen gas leaked from a pipe thread joint in a valve station. The…
The release occurred in the hydrogen storage system of a refuelling station. In the night a leakage occurred at one of the 120 high pressure bottles (800 bar). The leakage occurred at a screwed…
Malfunctioning of the non-return valve of the hydrogen compressor has caused the pressure between the hydrogen bottle and the compressor to rise to the maximum allowed pressure of 275 barg. As a…
A factory was evacuated after a tank began leaking hydrogen. No injuries were reported