Skip to main content

Release and Ignition of hydrogen due to a trailer collision (769)

This data is from the European Hydrogen Incidents and Accidents database HIAD 2.1, European Commission, Joint Research Centre.

Release and Ignition of hydrogen due to a trailer collision

A tractor - semitrailer with horizontally mounted cylinders filled with compressed hydrogen struck a northbound pickup truck that had veered in front of it. The tractor-semitrailer then lost control and overturned while continuing along the highway. It went off the road to the east and travelled 300 or more feet before it stopped (ca. 100 m). Because the valves, piping, and fittings at the rear of the semitrailer were not adequately protected and shielded from the impact caused by the rollover of the semitrailer, 8 of the 10 shutoff valves were sheared off, which resulted in the release and ignition of the hydrogen. One of the tubes separated from the trailer and came to rest at approximately 20 meters distance. It was This the tube which absorbed the initial impact with the roadway or terrain, resulting in the fracture of its front end and its ejection. In the meantime, the pickup truck had also run off the road. The pickup truck's fuel line ruptured, resulting in the truck being destroyed by fire.
Event Date
May 1, 2001
Record Quality Indicator
Event Initiating System
Classification of the Physical Effects
Nature of the Consequences
Cause Comments
The INITIATING CAUSE was the collision of the hydrogen trailer with another vehicles. ROOT CAUSE can be attributed generically to a human error (wrong manoeuvre). Contributing to the severity of the accident were the inadequate standards aiming at protecting and shielding cylinders, valves, piping, and fittings and at securing cylinders on the semitrailer.
Facility Information
Application
CGH2 tube trailer
Specific Application Supply Chain Stage
Components Involved
trailer with 10 horizontally mounted hydrogen cylinders
Storage/Process Medium
Actual Pressure
17
Design Pressure
17
Location Type
Location description
DESCRIPTION OF THE TRAILER LOAD The metal cylinder had nominal working pressure of 2,500 psig (ca. 170 bar) and a volume of 14100 cubic feet (ca. 400 m^3).
Operational Condition
Consequences
Number of Injured Persons
1
Number of Fatalities
1
Currency
Property Loss (onsite)

155000

Post-event Summary

One driver was killed, the other only injured. The cause of the fatality of the injuries were not hydrogen-related, but caused by the rad crash. Residents of five homes in the vicinity of the accident were asked to evacuate, and the highway was closed for more than 12 hours. Damage, clean-up, and lost revenues were estimated at $155,000.

Lessons Learned
SPECIFCIC LESSON LEARNT (1) The national hazardous materials regulations do not provide sufficient and clear requirements for protecting cylinders and valves, piping, and fittings of cylinders that are horizontally mounted on semitrailers. (2) Because horizontally mounted cylinders on semitrailers typically extend beyond the envelope of the bulkheads, the cylinders are exposed and vulnerable to initial impact with the roadway or terrain during rollover accidents and are at increased risk of damage, failure, and ejection. (3) It is possible that the lack of information could have increased the risk to emergency response personnel. GENERAL LESSON LEARNT As a result of its investigation, the US National Transportation Safety Board made the following safety recommendations to the Research and Special Programs Administration: 1. Modify the Code of Federal Regulations to clearly require that valves, piping, and fittings for cylinders that are horizontally mounted and used to transport hazardous materials are protected from multi-directional forces that are likely to occur during accidents, including rollovers. 2. Require that cylinders that transport hazardous materials and are horizontally mounted on a semitrailer be protected from impact with the roadway or terrain to reduce the likelihood of their being fractured and ejected during a rollover accident. 3. Revise the information about hydrogen in the North American Emergency Response Guidebook so that it specifically identifies the unique chemical and flammability properties of hydrogen.
Event Nature
Emergency Action
A very detailed Emergency Response record is given in the HAZMAT report in the references.
Release Type
Release Substance
H2 100%
Hydrogen Release Concentration (%)
0.00
Ignition Source
Detonation
No
Deflagration
No
High Pressure Explosion
No
High Voltage Explosion
No
Flame Type
References
References

Full NTSB report: https://www. ntsb. gov/investigations/Pages/DCA01MZ001. aspx (accessed Dec 2022)

Incident I-2003100615 of the US Pipeline and Hazardous Materials Safety Administration PHMSA: https://portal. phmsa. dot. gov/analytics/saw. dll?Portalpages&PortalPath=%2Fshared%2FPublic%20Website%20Pages%2F_portal%2FHazmat%20Incident%20Report%20Search (accessed September 2024)

NTBS news 17 September 2002 https://www. ntsb. gov/news/press-releases/Pages/NTSB_Determines_that_Securement_and_Protection_of_Hazmat_Containers_Was_Inadequate_in_Oklahoma_Truck_Accident. aspx

Report of the National Transportation Safety Board (NTSB) 17 September 2012, available at the link given (accessed June 2020)

Also in H2TOOLS https://h2tools. org/lessons/pickup-collides-tractor-pulling-hydrogen-tube-trailer-causing-tube-ejection-and-fire (accessed Sept 2025)