A LH2 was travelling on a highway early in the morning, when the driver lost the control of the vehicle, rolling over on the side of the road.
A liquid hydrogen trailer-tractor was travelling on a highway. Because of the snow and the ice underneath, the tractor slid off the road to the right and overturn. The police and fire department…
An accident involving a truck transporting hazardous goods occurred on the B 12. Three buildings were evacuated and three people were slightly injured. The road accident involved two cars and a…
This incident consisted in the accidental release of a CGH2 tube trailer after that it had rolled sideward on the ground. A hydrogen delivery company driver arrived at the customer site to…
While driving on a highway, the driver of a compressed hydrogen tube trailers lost control of the vehicle, which rolled on a side and stopped at the berm. The trailer was loaded with 5000 m3 of…
A truck was traveling on a highway carrying three hydrogen pallets. When trying to pass a vehicle ahead, the driver moved too far to the right, causing the wheels to hitting a snow-covered…
The trailer overturned and due to the impact released the whole trailer content to the atmosphere. After which the truck and the trailer could be put back on wheels. (The driver could not deliver…
The incident occurred on a large LH2 stationary storage tank at an aerospace testing facility. The cryogeninc tank experienced a significant vacuum leak in the insulation annulus, which eventually…
The pressurisation line on the nozzle skirt of a liquid hydrogen tank ruptured at welded section. Two tests were underway at the same time; one was a pressure test up to 1850 psi (ca. 128 bar) in…
During sampling tests on a facility LH2 dock transfer system, the system was pressurized to 15 psig when an expansion joint ruptured. Technicians proceeded with the pressure cycle with the main…
A full liquid hydrogen tanker left the home terminal with a internal pressure of 6 psig. Throughout the trip, drivers experienced nothing other than normal conditions. 12 hours later, at a scale,…
This event summarises 3 very similar cases of leaks at dispenser hoses during refuelling, occurred at the same hydrogen refuelling station in the period January - April 2017. The leaks triggered…
A fire broke out at an oil refinery and caused a hydrogen reformer to shut down.
The incident occurred in the new Residue Upgradation Facility unit of the refinery, which converts the heaviest oils from crude oil into high-quality, cleaner fuels such as Euro 6 diesel. The unit…
A small fire occurred at the vent stack of an ammonia processing unit in a plant producing fertilisers and other nitrogen-based chemicals. A safety shutdown procedure of the ammonia processing…
A leak occurred when transferring hydrogen from a trailer to the customer storage. The driver had just completed the pre-fill procedures and was starting to apply pressure to the fill hose, when…
"A leak occurred when transferring gaseous hydrogen from a tube trailer to the well of a hydrogen underground storage test facility. The leak was located at a threaded fitting which was part…
When a CGH2 tube trailer was backing into the terminal stall and getting ready to unhook the tractor a leak was detected on one of the cylinders. It was reported immediately to owner of the…
A driver found a small audible leak coming from the rear of the trailer compartment, while conducting in-trip visual walk-around inspection at a roadside. The driver set up perimeter around…